— 29 —
Section
Parameter
Notes
CHARGED_VOL=x|UNKNOWN
x — from 1.0 to 40.0,
one decimal place.
Factory setting: 13.2
One of the 3 charged criteria: voltage
(in volts) which is sufficient to consider
the battery as fully charged when
the battery voltage remains above this
value. This parameter should always
be slightly (0.3..0.5V) lower than
the cut-off (the end of charge) voltage
of the charger.
UNKNOWN sets voltage to the default
value for Lead Acid and Lithium
Ion battery types, see Table 1 in X.3.
Use UNKNOWN for NiCD, NiMH
batteries.
CHARGED_CUR=x
x — from 0.5 to 10.0, one
decimal place.
Factory setting: 4.0
One of the 3 charged criteria:
if the charge current drops below
this value (expresses as a percentage
of the nominal capacity), the battery
is considered as fully charged.
CHARGED_PERIOD=x
x — integer from 1 to 50.
Factory setting: 3
One of the 3 charged criteria:
time period (in minutes) during
which voltage and current
conditions set in CHARGED_VOL
and CHARGED_CUR parameters
should be met to consider the battery
as fully charged.
BATTERY_TYPE
=FLOODED|GEL|AGM|UNKNONN
Factory setting:
FLOODED
Battery type in PGN 127513 «Battery
Configuration Status» (for reporting
only).
Table 1 continued