— 43 —
Syntax
Examples
Description
YD:FULL_SYNC [ON|OFF]
YD:FULL_SYNC ON
Run/stop Full Synchronization
with the battery (see Section X).
Without parameters, the command
displays the current value (ON
or OFF), and the current state
of synchronization process, if Full
Synchronization is in progress.
YD:SOC
YD:SOC
Returns current State of Charge
value and the date of last Partial
Synchronization.
YD:SOH
YD:SOH
Returns current State
of Health value and the date
of last Full Synchronization.
If Full Synchronization is on (see
«YD:FULL_SYNC» above or section
IX.1, «FULL_SYNC» in Table 1) this
also returns the current state of Full
Synchronization process.
YD:CONSUMED_AH
YD:CONSUMED_AH
Returns number of consumed Ah
value.
YD:MARETRON [ON|OFF]
YD:MARETRON ON
Sets compatibility mode
for Maretron and Carling Tech
digital switching equipment (see
IX.1, Note 3 to Table 1).
Factory setting: OFF
Table 1 continued