Chassis Management Displays
Field
Means
Run
The module is inhibited either because a user pushed the
Inhibited
Reset button once, or a user issued a RESET CHASSIS SLOT
HOLD command for the module in this slot.
Init Menu
The Network 9000 processor module is running the
initialization configuration menu.
ROM Wait The processor module failed to obtain the software load
image using the information in the enabled initialization
records, although this information may be valid. For
example, the load server specified in the initialization
record may be unavailable. The processor module is now
waiting for a period of time, from 5 to 12 minutes, before it
attempts to load again using the information in the
initialization records. Depending on the problem, you may
be able to correct this condition by changing the information
in the initialization records with the DEFINE CHASSIS
SLOT commands, described in Chapter 4.
Invalid CS The processor module failed to obtain the software load
image because the information in the control storage area
was invalid or corrupt. To correct this condition, you can
change the information in the initialization records with the
DEFINE CHASSIS SLOT commands, described in Chapter
4.
Suspended The processor module is not operational because it has been
inhibited either because a user pushed the Reset button on the
front panel once, or a user entered the RESET CHASSIS
HOLD command for the module in this slot. To reactivate
the processor module, press the Reset button or enter the
RESET CHASSIS command, described in Chapter 6.
Diagnostics The processor module is running diagnostic programs.
Failed
The processor module was running diagnostics programs,
and these programs failed. If this status appears, contact
your Xyplex representative for more information.
Not
The Single Chip Microcontroller (SCM) on the module
Responding responded to the request for status, but the operational
software did not. When this status appears, other fields in
the display, including Installed Memory, Link Mappings,
and Uptime do not have status. If the module in the slot
returns the status Not Responding, wait 30 seconds and enter
the Slot Status command for the module in this slot again. If
the module still returns the status Not Responding, contact
your Xyplex representative.