Chassis Management Displays
Field
Means
The hardware type and serial number of the Network 9000 processor
module. If a Type 1 product is present in this slot,
Unknown
appears in this
field.
Processor
Module
I/O Module
The hardware type and serial number of the I/O module. If a MAXserver
card is present in this slot,
AC/119
or
MX/101
appears in this field.
The version of firmware running on each processor module in the
chassis.
Firmware
The number of a PS/130 power supply in the chassis. (If PS/120 power
supplies exist in the chassis, they do not appear in this field.)
Power
The current state of the power supply. Possible states are these:
Required
This power supply must be available to support the modules
in the chassis. Other power supplies cannot compensate for
its power if a required power supply becomes disabled.
Redundant This power supply need not be available to support the
modules in the chassis. Other power supplies can
compensate for its power if it becomes disabled. If two or
more redundant power supplies become disabled, however,
other power supplies do not necessarily compensate for the
loss of power. A chassis with three redundant power
supplies, for example, can require at least two to be in use.
Disabled
This power supply is not providing power to the slots in the
chassis.
Status:
Hardware
The managed power supply type.
The serial number of the power supply.
Serial #
This field reflects the current and historical warnings. Current
warnings are those which have occurred in the last four seconds, since the
most current update. Historical warnings are those that have occurred
prior to the most current update.
Warnings
The maximum amount of power each power supply can deliver and the
actual (current) amount of power each power supply is delivering.
Power
The total amount of maximum power and used power generated by all
power supplies in the chassis.
Chassis Total
86