Chassis Management Displays
Field
Means
The hardware type of each power supply.
Hardware
Voltage levels
+5V +12V -12V
The theoretical rating of the maximum power for each voltage level. The
total of these individual rated values may exceed the maximum rated
total of the power supply. In actual use, the total of the individual levels
would not exceed the total rated power.
The theoretical rating of the total maximum power for this power supply.
(The power supply total may be less than the total of the individual
estimates at each voltage level.)
Total
This is the total of the theoretical rating of the maximum power for each
voltage level of all power supplies in the chassis. The total reflects the
maximum combined power for all power supplies in the chassis. (The
Max. Power Provided Total may be less than the individual totals for
each voltage level.)
Max. Power
Provided
The actual power consumed by the modules in the chassis at each voltage
level. The Total reflects the actual combined values of Power Consumed
at each voltage level.
Power
Consumed
Power
Available
The value of the Max. Power Provided minus the Power Consumed at each
voltage level. The Total reflects the combined Power Available for each
voltage level.
The number of a chassis slot.
Slot
The module types in each slot. The first column lists the processor
module, if it exists, and the second column lists the I/O module, if it
exists. The type Unknown can indicate either that the Processor or I/O
portion of the slot is empty or that a Type 1 card MAXserver card exists in
the slot.
Hardware
The maximum possible power at each voltage level available to the
modules in each slot. The Total reflects the combined maximum possible
power of each voltage level for each slot.
Voltage levels
+5V +12V -12V
The combined maximum possible power at each voltage level that can be
used by the modules in all slots. The Total reflects the combined
maximum possible power used by the modules in all slots.
Worst Case
Power
88
0020