Managing the Operational Link Map
DEFINE [SERVER] CHASSIS SLOT
Change a connection in the link map
The DEFINE [SERVER] CHASSIS SLOT command changes the link
connection on a managed Network 9000 module, such as a managed
concentrator, a terminal server, a LAN bridge/router, or a WAN
bridge/router to either a midplane Ethernet segment or an external LAN.
When you use this command, the change takes effect immediately.
Notes
Certain combinations of keywords are not valid on all products. For
example, you cannot specify an external link on a terminal server. If
you attempt to specify a connection that is not valid for a particular
product, the command interface generates an error message. The first
part of this chapter describes the possible connections in the link map for
each product.
A Management Processor 210 can change the Ethernet link of a
concentrator I/O module in a target slot. For other products, this
command is valid only on the processor module where you are logged on.
Privilege
Level
Privileged
Syntax
DEFINE [SERVER] CHASSIS SLOT [#] [LINK] [identifier] selection |
[SEGMENT DISABLED]
Where
Means
[LINK]
Change a link on this module. This keyword is optional.
An optional variable which indicates the number of a chassis slot holding
a concentrator I/O module. This variable does not apply to other Network
9000 products. You can specify a target slot only from a Management
Processor.
[# ]
46