![Xylem Aanderaa Motus 5729 Operating Manual Download Page 113](http://html1.mh-extra.com/html/xylem/aanderaa-motus-5729/aanderaa-motus-5729_operating-manual_3837216113.webp)
August 2020 – TD 316 OPERATING MANUAL – Motus Wave Sensor 5729
Page 113
Figure 10-3: Mounting considerations EMM 2.0
.
10.4.1
Magnetic distortion areas on EMM 2.0
•
Areas around parts made of steel. See figure 5.
1.
Top triangle (hot dip galvanized steel).
2.
Bottom frame (hot dip galvanized steel).
•
Due to the magnetic influence from metal parts on a standard EMM 2.0 it is recommended to add an external
compass to the sensor or to the system.
•
NOTE! After external compass has been mounted avoid mounting magnetic objects in the vicinity of the
compass.
10.4.2
Recommended sensor location
•
It is difficult to avoid magnetic distortion areas on the lower parts of an EMM 2.0. It is therefore recommended to
add an external compass to the system.
•
The best location for mounting the sensor is:
1.
As close to the center of the buoy as possible.
2.
As close to the waterline as possible.
-
For buoys with central canister it is recommended to mount the sensor inside the canister.
-
For buoys without central canister the sensor can be fixed to the surface of the buoy flotation.
10.4.3
Connecting cables
•
Refer to chapter 10.2 in this document.
2. Bottom frame
1. Top triangle
Recommended external
compass location
Recommended
sensor location (top
of flotation or inside
canister).