Chapter 4 - SCSI Installation (XVME-956/412)
CHARACTERISTICS
SPECIFICATION
Power Requirements
+5V 0.43 A, typical
0.63 A, maximum
Temperature
0 - 65° C
Compatibility
Compatible with XVME-956 expansion scheme and any
CPU modules compatible with that scheme
The two SCSI devices at each end of the bus need to have terminating resistors installed for proper
operation. A l l other SCSI devices must have their terminators removed. The module provides optional
termination, in the form of three sip sockets, with terminating sip resistors installed at the factory.
These are RN3, 4, and 5. Remove these resistor networks if the module is not on an end of the SCSI
cable.
Another consideration is that of target number assignment. Each device on the SCSI bus needs to have
a unique target number (ID) assigned.
4.6 S P E C I F I C AT I O N S
Table 4-3 lists the various operational specifications for the SCSI adapter module.
Table 4-3. SCSI Specifications
4-12
•
•
•