background image

6

7

GENERATOR ‘EARTHING’

Always ensure that this generator is “Earthed” correctly 
before using. “Earthing” stake and wire has been supplied 
with this generator ensure it is used to ensure your safety, 
see page 11. 

BEWARE OF CHILDREN & PETS

Children and pets should be kept out of the operating 
area. Children should not be allowed to touch or operate 
generators or touch extension cords. All generators should 
be kept out of reach of children. When NOT in use keep 
the generator preferably stored or locked in a secure well 
ventilated cabinet or room with the fuel tank empty.

GUARD AGAINST ELECTRIC SHOCK

Never touch the generator with wet or damp hands as 
electric shock may occur. Always ensure your generator is 
connected to ground, i.e. Earthed with the supplied earth 
stake, see page 11.

OPERATING ENVIRONMENT

NEVER use your generator indoors. Your generator 
produces deadly carbon monoxide and this is harmful and 
can caused death. Only use your generator in well ventilated 
areas like the outdoors. Do not expose your generator to 
rain or use in damp or wet locations. Do not expose your 
generator to direct sunlight. Keep the work area well lit. 
Do not use your generator in areas where there is a risk 
of explosion or fire from combustible materials, flammable 
liquids, paint, varnish, petrol, etc flammable gases and dust 
of an explosive nature. As a precaution it is recommended 
that you consult an expert on selecting and using a 
suitable fire extinguisher and have it available for use in an 
emergency when operating the generator.

PERSONAL SAFETY

Clothing

Do not wear loose clothing, jewellery or anything that could 
get caught in moving machinery. Gloves may be worn when 
filling generator with fuel.

Hair

 

Long hair should be tied back or contained in a protective 
covering.

Eye Protection

The use of safety goggles is highly recommended (normal 
glasses are not sufficient for eye protection) when using 
or refuelling generators. Prescription glasses do not have 
safety lenses.

Footwear

Where there is the risk of heavy objects or if there is a 
risk of slipping on wet or slippery doors, suitable non–slip, 
covered, safety footwear should be worn. Protect your feet 
from dropping accidents. 

Ear Protection

The use of ear protection is highly recommended when using 
generators. The continual noise may damage your ears.

Respiratory Protection

Always wear approved breathing protection when decanting 
fuel. ALWAYS use this generator in well ventilated area. 
Never use indoors.

Warning! Do not breathe in exhaust fumes. Exhaust fumes 
are poisonous and may cause drowsiness, unconsciousness 
and even death.

Do Not Over Reach

Do not over reach. Keep a proper footing and maintain your 
balance at all times. Avoid using abnormal stances and 
awkward body positions.

Stay Alert

Watch what you are doing, use common sense, and never 
operate a generator when you are tired, drinking alcohol, 
taking drugs or if taking medication that causes drowsiness.

WARNING!

Do not attempt to modify the generator in any way; this will VOID your warranty.

The use of any attachment or accessory other than those recommended in this instruction manual could result in damage 
to the generator and could cause injuries to the operator.

This petrol generator complies with Australian / New Zealand and International standards and safety requirements. 
Repairs should only be carried out by qualified persons using original spare parts. Failure to do so may result in 
considerable danger to the operator.

Summary of Contents for XTM2000DG

Page 1: ...ENGINE OIL AND WILL NOT START UNTIL FILLED TO THE CORRECT LEVEL Oil type 4 stroke fully synthetic motor oil SAE 15W 40 API SN Category Oil Capacity 400ml Approximately Refer to page 8 and page 10 wit...

Page 2: ...se attach the purchase receipt to this manual and ensure both are kept safe We hope you enjoy your new generator and if you have any problems call customer service on the above phone numbers Do not re...

Page 3: ...g and trouble free service life from your generator This generator is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and...

Page 4: ...nformation please contact customer service Australia 1300 660 457 New Zealand 0800 474 876 CONTACT DETAILS Smart Marketing Group Pty Ltd 33 35 Lionel Road Mt Waverley Victoria 3149 Australia Tel 613 9...

Page 5: ...oolant on the generator as a fatal electric shock could occur Never use coolant in the generator as damage may occur Do not touch the generator with wet hands as this may cause electrocution Never use...

Page 6: ...moving machinery Gloves may be worn when filling generator with fuel Hair Long hair should be tied back or contained in a protective covering Eye Protection The use of safety goggles is highly recomm...

Page 7: ...elect the right generator for the job Do not use a generator to do a job for which it was not designed Do not force a small generator to do the job of a heavy duty generator Any damage caused by overl...

Page 8: ...store your unleaded petrol ULP in before decanting into the fuel tank If contaminated dirty or old stale fuel is used any damage caused will not be covered under warranty OIL CHECK DAILY ONLY USE 4 S...

Page 9: ...indicator red This indicator light is on when the generator is overloaded when the red light turns on the power supply will be automatically disconnected Check the attached products power requirement...

Page 10: ...at the bottom 3 Use oil as detailed on page 8 4 stroke fully synthetic motor oil SAE 15W 40 API SN Category 4 Ensure generator is level when filling with oil DO NOT TIP USE A FUNNEL NOT SUPPLIED 5 Rem...

Page 11: ...ON 1 Ensure the Earth stake and wire are attached Pic 5 2 Turn the fuel cap breather lever clockwise to ON Note If fuel cap breather is not on generator will not operate correctly 3 Turn the fuel tap...

Page 12: ...witch economy smart switch to OFF Pic 11 4 Turn fuel tap and engine switch clockwise to OFF Pic 12 PIC 10 PIC 11 PIC 12 PIC 9 WARNING Never pull the recoil once the engine has started Any damage cause...

Page 13: ...he problem before using the generator 2 Lift the flap and plug your appliance into the outlet socket on the face plate 3 Turn the appliance on and use as per the manufacturers manual 4 When finished t...

Page 14: ...nce s required power is greater than the generator s output check the appliances wattage requirements refer Page 13 Output indicator light green will remain ON during operation However if it goes out...

Page 15: ...d fuel responsibly 6 Fit access panel at the bottom then position at top and secure with screws 2pcs 1 Remove fuel tank cap 2 Remove the fuel tank filter 3 Position a fuel safe container next to the g...

Page 16: ...for cracks or damage Replace if required Exhaust system Check for leakage Tighten or replace gasket if required Check exhaust screen Clean and replace if required Carburettor Check choke operation Fi...

Page 17: ...properly gapped and free of deposits in order to ensure proper engine operation To check 1 Remove the spark plug cover 2 Remove the spark plug cap Pic 18 3 Clean any dirt from around base of spark pl...

Page 18: ...enerator to drain the oil out of the oil fill 8 Once oil sump is empty place generator on its feet wipe up any spills 9 Replace oil filler cap If changing oil refer to page 10 for oil filling details...

Page 19: ...pplied with fuel Poor spark Pull Recoil Quickly Clean tank Clean fuel line Fill with Correct Fuel See Page 8 Rotate START Switch to ON Spark plug dirty with carbon or wet with fuel Clean spark plug Da...

Page 20: ...onsult Service Agent Generator problem Indicator light OFF No AC output Output power too high or low EngineRPM set too highor low Consult Service Agent Loose Consult Service Agent t n e n o p m o c In...

Page 21: ...TER SPARK PLUG Authorised Service Agent Name or Company Stamp Technician Date This service is to be completed within 36 hours or 9 months of purchase which ever comes first REPLACE CHECK ADJUST ENGINE...

Page 22: ...22 This page has been left intentionally blank...

Page 23: ...ATEGORY Fuel tank capacity 4 2L Fuel type Unleaded 91 Petrol no ethanol Spark plug A7RTC Rated voltage 230 240V AC 50Hz Rated output 1800W Maximum output 2000W Rated current 7 5A Power factor 1 0 Maxi...

Page 24: ...ROUP AUSTRALIA PTY LTD Mon Fri 8 00am 5 00pm AEST Do not return to place of purchase Keep your purchase receipt this will be required to make any claims under the 12 month warranty Australia 1300 660...

Reviews: