background image

4

5

•  Never connect this generator to a second generator.
•  Never connect this generator to Commercial or Domestic 

power supply.

•  Always use the generator in an open well ventilated area.
•  Unit will become hot during use. Please keep generator 

at least one metre (1m) away from buildings, other 
equipment, pedestrian areas or flammable materials.

•  Never pull the re-coil starter once the generator engine 

has started. Any damage caused will not be covered by 
warranty.

•  Never start or stop the generator with any appliances 

attached.

•  Ensure the generator has stopped before servicing, or 

lubricating etc.

•  Do not attempt to modify the generator, guards or the 

supplied accessories in any way.

•  Do not touch the exhaust. This can become very hot 

during operation and can cause serious burns.

•  Always check the generator for damaged parts or fuel 

leaks, ensure these are fixed before using it.

•  Never refuel while smoking or in the vicinity of an open 

flame.

•  Always wear safety eye wear, ear and breathing 

protection when operating or refuelling the generator.

•  To avoid a fire if you spill fuel while refuelling, clean up 

before starting the generator.

•  Never operate or store the generator on its side, 

ALWAYS operate or store in an upright manner on firm, 
solid ground.

•  Your generator is factory set, NEVER attempt to speed 

it up as this could endanger the user and damage the 
generator and/or attached appliances.

•  Never operate the generator in damp, wet or flooded 

conditions.

•  Before plugging appliances into the generator allow it to 

run up to full speed.

•  If the generator makes an unfamiliar sound or vibrates 

excessively, switch the generator ‘OFF’ immediately. 
Investigate the possible cause or consult your authorised 
service agent.

•  Do not use ANY type of coolant on the generator as a 

fatal electric shock could occur.

•  Never use coolant in the generator as damage may occur.
•  Do not touch the generator with wet hands as this may 

cause electrocution.

•  Never use your generator on highly conductive surfaces. 

e.g. Steel walk ways, metal roof or metal bench, as this 
could cause an electric shock.

•  Always operate your generator at least two (2) metres 

away from conductive surfaces.

•  Locate this generator in a convenient place, avoid using 

long extension leads.

•  If an extension lead is used, avoid leaving it where it may 

be damaged by pedestrian or vehicular traffic or cause a 
trip and fall hazard.

•  Always observe normal safety precautions with ALL 

appliances used with this generator.

•  Never transport the generator with fuel in the tank. 

ALWAYS empty the fuel tank.

•  All loads must be kept within the ratings stated on the 

name plate. Overloading the generator will damage the 
unit or shorten its life. This will not be covered under 
warranty.

•  Do not tamper or alter any parts as this may cause 

personal injury or damage the generator.

•  Always disconnect any loads before starting or stopping 

the generator.

•  When storing the generator always store in a secure well 

ventilated area.

•  Always store in an upright position. NEVER store or lay 

this generator on its side.

    

  

WARNING!

Do not use the generator in areas where there is a risk of 
explosion or fire from combustible materials. The sparks 
possibly caused when using this generator may ignite 
combustible materials as well as flammable liquids, 
paint, varnish, petrol, flammable gases and dust of an 
explosive nature. As a precaution it is recommended 
that you consult an expert on a suitable fire extinguisher 
and its use. Ensure that the work area is kept clear of 
combustible materials.

WARNING!

Do not use the generator indoors or in confined spaces 
where exhaust gases, smoke or fumes could reach 
dangerous concentrations.

SPECIFIC SAFETY INSTRUCTIONS

Summary of Contents for XTM2000DG

Page 1: ...ENGINE OIL AND WILL NOT START UNTIL FILLED TO THE CORRECT LEVEL Oil type 4 stroke fully synthetic motor oil SAE 15W 40 API SN Category Oil Capacity 400ml Approximately Refer to page 8 and page 10 wit...

Page 2: ...se attach the purchase receipt to this manual and ensure both are kept safe We hope you enjoy your new generator and if you have any problems call customer service on the above phone numbers Do not re...

Page 3: ...g and trouble free service life from your generator This generator is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and...

Page 4: ...nformation please contact customer service Australia 1300 660 457 New Zealand 0800 474 876 CONTACT DETAILS Smart Marketing Group Pty Ltd 33 35 Lionel Road Mt Waverley Victoria 3149 Australia Tel 613 9...

Page 5: ...oolant on the generator as a fatal electric shock could occur Never use coolant in the generator as damage may occur Do not touch the generator with wet hands as this may cause electrocution Never use...

Page 6: ...moving machinery Gloves may be worn when filling generator with fuel Hair Long hair should be tied back or contained in a protective covering Eye Protection The use of safety goggles is highly recomm...

Page 7: ...elect the right generator for the job Do not use a generator to do a job for which it was not designed Do not force a small generator to do the job of a heavy duty generator Any damage caused by overl...

Page 8: ...store your unleaded petrol ULP in before decanting into the fuel tank If contaminated dirty or old stale fuel is used any damage caused will not be covered under warranty OIL CHECK DAILY ONLY USE 4 S...

Page 9: ...indicator red This indicator light is on when the generator is overloaded when the red light turns on the power supply will be automatically disconnected Check the attached products power requirement...

Page 10: ...at the bottom 3 Use oil as detailed on page 8 4 stroke fully synthetic motor oil SAE 15W 40 API SN Category 4 Ensure generator is level when filling with oil DO NOT TIP USE A FUNNEL NOT SUPPLIED 5 Rem...

Page 11: ...ON 1 Ensure the Earth stake and wire are attached Pic 5 2 Turn the fuel cap breather lever clockwise to ON Note If fuel cap breather is not on generator will not operate correctly 3 Turn the fuel tap...

Page 12: ...witch economy smart switch to OFF Pic 11 4 Turn fuel tap and engine switch clockwise to OFF Pic 12 PIC 10 PIC 11 PIC 12 PIC 9 WARNING Never pull the recoil once the engine has started Any damage cause...

Page 13: ...he problem before using the generator 2 Lift the flap and plug your appliance into the outlet socket on the face plate 3 Turn the appliance on and use as per the manufacturers manual 4 When finished t...

Page 14: ...nce s required power is greater than the generator s output check the appliances wattage requirements refer Page 13 Output indicator light green will remain ON during operation However if it goes out...

Page 15: ...d fuel responsibly 6 Fit access panel at the bottom then position at top and secure with screws 2pcs 1 Remove fuel tank cap 2 Remove the fuel tank filter 3 Position a fuel safe container next to the g...

Page 16: ...for cracks or damage Replace if required Exhaust system Check for leakage Tighten or replace gasket if required Check exhaust screen Clean and replace if required Carburettor Check choke operation Fi...

Page 17: ...properly gapped and free of deposits in order to ensure proper engine operation To check 1 Remove the spark plug cover 2 Remove the spark plug cap Pic 18 3 Clean any dirt from around base of spark pl...

Page 18: ...enerator to drain the oil out of the oil fill 8 Once oil sump is empty place generator on its feet wipe up any spills 9 Replace oil filler cap If changing oil refer to page 10 for oil filling details...

Page 19: ...pplied with fuel Poor spark Pull Recoil Quickly Clean tank Clean fuel line Fill with Correct Fuel See Page 8 Rotate START Switch to ON Spark plug dirty with carbon or wet with fuel Clean spark plug Da...

Page 20: ...onsult Service Agent Generator problem Indicator light OFF No AC output Output power too high or low EngineRPM set too highor low Consult Service Agent Loose Consult Service Agent t n e n o p m o c In...

Page 21: ...TER SPARK PLUG Authorised Service Agent Name or Company Stamp Technician Date This service is to be completed within 36 hours or 9 months of purchase which ever comes first REPLACE CHECK ADJUST ENGINE...

Page 22: ...22 This page has been left intentionally blank...

Page 23: ...ATEGORY Fuel tank capacity 4 2L Fuel type Unleaded 91 Petrol no ethanol Spark plug A7RTC Rated voltage 230 240V AC 50Hz Rated output 1800W Maximum output 2000W Rated current 7 5A Power factor 1 0 Maxi...

Page 24: ...ROUP AUSTRALIA PTY LTD Mon Fri 8 00am 5 00pm AEST Do not return to place of purchase Keep your purchase receipt this will be required to make any claims under the 12 month warranty Australia 1300 660...

Reviews: