12
13
6. Hold down the generator firmly with one hand on the
frame, then pull the recoil starter slowly until engaged,
then pull briskly, Pic. 9. This step may need to be
repeated until generator engine starts, this can take up
to about 12 pulls.
7. Allow engine to run up to speed, this usually takes up to
about 5-10 seconds.
8. Slowly turn choke to OPEN / RUN by sliding the choke
lever to the left, Pic. 10.
9. Check that the only illuminated light is the green output
power light. The generator will be running and ready for
use.
1. Ensure all power leads and appliances have been
switched off and disconnected from the generator power
socket.
2. Allow generator to run for 1-2 minutes, this allows the
generator to cool down.
3. Switch economy smart switch to OFF, Pic. 11.
4. Turn fuel tap and engine switch clockwise to OFF, Pic. 12.
PIC. 10
PIC. 11
PIC. 12
PIC. 9
WARNING!
Never pull the recoil once the engine has started. Any
damage caused will not be covered under warranty.
WARNING!
Before connecting any electrical load to the generator
ensure that the load does not exceed the maximum load
as stated on the rating plate and also check page 13 for
extra details.
Ensure that the mains supply lead is long enough to
reach the generator without any strain.
WARNING!
Never stop your generator with electrical appliances or
power leads attached. Always remove power leads and
appliances before stopping your generator.
In case of emergency, the easiest way to stop the
generator is to directly turn engine switch to OFF
position.
Avoid doing so in non-emergency circumstances as it
carries the risk of damaging the generator.