66
Login config
Admin account login config with (1) Auto logout setting, (2) Admin
login lock
Password
Admin password value with (1) Current password, (2) Old
password
Date
Time Zone setting
Event log mail setting with (1) Mail_from address, (2) SMTP
server, (3) Authentication, (4) Mail account ID, (5) Mail password,
(6) Mail_To_1 address, (7) Mail_To_2 address, (8) Mailt_To_3
address, (9) Event log filter setting
SNMP
SNMP setting with (1) SNMP trap address 1, (2) SNMP trap
address 2, (3) SNMP trap address 3, (4) Community setting, (5)
Event log filter function
Event log
Event log filter setting with (1) Web UI and console UI setting, (2)
LCM setting, (3) Web UI pop up event setting
SES config
SES management setting
vol_temp
Auto shutdown setting
UPS
UPS setting with (1) UPS type, (2) Shutdown Battery Level, (3)
Shutdown Delay, (4) Shutdown UPS
Physical disk
Not available in import function.
Current controller hard disk status with (1) size, (2) block size, (3)
VG, (4) hard status
Physical disk
spindown
Not available in import function.
Hard disk auto spindown setting
Volume group
Not available in import function.
VG setting with (1) VG name, (2) size, (3) number of physical
disks, (4) number of UDVs, (5) RAID level
Cache volume
Not available in import function.
Cache volume setting with (1) size, (2) percentage
User data volume
Not available in import function.
UDV setting with (1) UDV name, (2) size, (3) VG name, (4) cache
volume, (5) Stripe height, (6) block size, (7) write through or write
back, (8) priority
Logical unit
Not available in import function.
LUN setting with (1) host name, (2) target name, (3) UDV name,
(4) LUN number, (5) permission
Summary of Contents for xl-raid-2804issa
Page 1: ...XL RAID 2804ISSA iSCSI SATA II SUBSYSTEM Installation and Configuration Manual Revision 1 0 ...
Page 84: ...84 4 Click OK 5 Click Targets ...
Page 93: ...93 Click Advanced Select Target Portal to iSCSI data port 1 192 168 11 229 Then click OK ...
Page 95: ...95 ...
Page 101: ...101 Log on Enable Enable multi path checkbox Then click Advanced ...
Page 102: ...102 Select Target Portal to iSCSI data port 1 192 168 11 229 Then click OK Log on again ...
Page 104: ...104 iSCSI device is connected Click Details Click Device tab then click Advanced ...
Page 105: ...105 Click MPIO tab select Load Balance Policy to Round Robin Click Apply ...
Page 110: ...110 The MC S setting is done ...
Page 112: ...112 Disable Immediate Data and enable Initial R2T Click OK ...
Page 115: ...115 Then run Computer Management in Windows Make sure the disk appears ...