7
1.2 Technical Specifications
Form Factor: 2U 19-inch rackmount chassis
RAID processor: Intel IOP341 64-bit
RAID Level: 0, 1, 0+1, 3, 5, 6, 10, 30, 50, 60 and JBOD
N-way mirror (N copies of the disk)
Cache memory: 512MB ~ 2GB DDR II
No. of channels (host + drive): 2 + 8
Host bus interface: 1Gb/s Ethernet
Drive bus interface: 3Gb/s SATA II
Hot-swap drive trays: Eight (8) 1-inch trays
Host access control: Read-Write & Read-Only
Supports CHAP authentication
802.3ad port trunking, LACP support
Jumbo frame support
Maximum logical volume: up to 256
Maximum host connection: up to 32
Maximum host clustering: up to 8 for one logical volume
Manual/scheduling volume snapshot: up to 32
Snapshot rollback mechanism support
Supports Microsoft Multipath I/O (MPIO)
Global/dedicated cache configurable by volume
Global and dedicated hot spare disks
Online Volume migration
Online Volume sets expansion
Configurable stripe size
Instant RAID volume availability and background initialization support
Supports over 2TB per volume
Online consistency check
Bad block auto-remapping
S.M.A.R.T. support
Summary of Contents for xl-raid-2804issa
Page 1: ...XL RAID 2804ISSA iSCSI SATA II SUBSYSTEM Installation and Configuration Manual Revision 1 0 ...
Page 84: ...84 4 Click OK 5 Click Targets ...
Page 93: ...93 Click Advanced Select Target Portal to iSCSI data port 1 192 168 11 229 Then click OK ...
Page 95: ...95 ...
Page 101: ...101 Log on Enable Enable multi path checkbox Then click Advanced ...
Page 102: ...102 Select Target Portal to iSCSI data port 1 192 168 11 229 Then click OK Log on again ...
Page 104: ...104 iSCSI device is connected Click Details Click Device tab then click Advanced ...
Page 105: ...105 Click MPIO tab select Load Balance Policy to Round Robin Click Apply ...
Page 110: ...110 The MC S setting is done ...
Page 112: ...112 Disable Immediate Data and enable Initial R2T Click OK ...
Page 115: ...115 Then run Computer Management in Windows Make sure the disk appears ...