76
and the data in it just like it finished rollback. At the same time, the other related snap
UDV(s) can not be accessed.
4.
After rollback process finished, the other related snap UDV(s) will be deleted, and
snapshot space will be set to
0
.
IMPORTANT! Before executing rollback, it is better to dismount file
system for flushing data from cache to disks in OS first.
4.5 Disk Roaming
Physical disks can be re-sequenced in the same system or move whole physical disks from system-
1 to system-2. This is called disk roaming. Disk roaming has some constraints as described in the
following:
1.
Check the firmware of two systems first. It is better that both have same firmware
version or newer.
2.
Whole physical disks of related VG should be moved from system-1 to system-2
together. The configuration of both VG and UDV will be kept but LUN configuration will
be cleared to avoid conflict with system-2.
4.6 Support Microsoft MPIO and MC/S
MPIO (Multi-Path Input/Output) and MC/S (Multiple Connections per Session) both use multiple
physical paths to create logical "paths" between the server and the storage device. In the case
which one or more of these components fails, causing the path to fail, multi-path logic uses an
alternate path for I/O so that applications can still access their data.
Microsoft iSCSI initiator supports multi-path function. Please follow the procedures to use MPIO
feature.
1.
A host with dual LAN ports connects cables to
XL-RAID-2804ISSA
.
2.
Create a VG/UDV, attach this UDV to the host.
3.
When installing
“Microsoft iSCSI initiator”
, please install MPIO driver at the same
time.
4.
Logon to target separately on each port. When logon to target, check “Enable multi-
path”. Please refer to Appendix D, step 6.
5.
MPIO mode can be selected on Targets
Details
Devices
Advanced.
6.
Rescan disk.
7.
There will be one disk running MPIO.
Summary of Contents for xl-raid-2804issa
Page 1: ...XL RAID 2804ISSA iSCSI SATA II SUBSYSTEM Installation and Configuration Manual Revision 1 0 ...
Page 84: ...84 4 Click OK 5 Click Targets ...
Page 93: ...93 Click Advanced Select Target Portal to iSCSI data port 1 192 168 11 229 Then click OK ...
Page 95: ...95 ...
Page 101: ...101 Log on Enable Enable multi path checkbox Then click Advanced ...
Page 102: ...102 Select Target Portal to iSCSI data port 1 192 168 11 229 Then click OK Log on again ...
Page 104: ...104 iSCSI device is connected Click Details Click Device tab then click Advanced ...
Page 105: ...105 Click MPIO tab select Load Balance Policy to Round Robin Click Apply ...
Page 110: ...110 The MC S setting is done ...
Page 112: ...112 Disable Immediate Data and enable Initial R2T Click OK ...