32
www.XSscuba.com
XS Scuba Inspire Regulator Service Manual
E. Once the lever is at its maximum height, drive the
crown orifice in, CW, an additional 1/8th turn / 45
degrees.
F. Depress and release the lever several times to
insure an airtight seal when the lever is released. This
adjustment procedure sets the valve as the minimum
cracking and minimum diver controlled breathing
effort.
G. Turn off the air supply and purge the 2nd stage by
pressing the lever (19) . Pull back on the adjustment
wheel and remove the in-line tool from the 2nd stage.
Remove the MP hose from the inline tool.
CAUTION: When removing the inline adjustment
tool from the second stage, remember to pull the
handwheel back to disengage it from the crown
orifice. Failure to perform this step can cause
changes to the regulator’s adjustment.
9. Continuation of Assembly
A. Install the diaphragm (9)
i. Position the diaphragm (9) into the main
housing (1). Use the back of the TL136
Multi-Purpose Tool to work the edges of the
diaphragm into place.
B. Install the thrust washer (10) over the top of the
diaphragm (9).
C. Install the front purge cover (11)
i. Place the front cover (11) on top of the thrust
washer (10).
D. Thread on the front cover retaining ring (12).
i. Dip the front cover retaining ring (12) into
a dish of soapy water to lubricate it.
ii. While holding the front cover (11) stationary
with your thumb, tighten down the front cover
retaining ring (12). Tighten it until snug using the
TL117 Front Cover Tool.
E. Install the exhaust cover on the main housing
i. Engage the left tab first, then engage the right
clip until you hear it lock into place
8E
45 degree
9A
9B
9C
9D