30
www.XSscuba.com
XS Scuba Inspire Regulator Service Manual
6. Install the Completed Valve Assembly into the
Main Housing (1)
A. While keeping the lever depressed, slide the valve
body assembly through the venturi deflector and into
the main housing. DO NOT allow the lever to spring
up forcefully as it passes through. Guide it up slowly.
B. Confirm that the lever feet are between the molded
tabs on the box bottom.
CAUTION: Confirm that the lever feet are
between the molded tabs on the box bottom. This
retains the lever feet so that they don’t back out of
the valve housing.
C. Install the valve housing o-ring (6) on to the
threaded end of the valve housing (17).
D. Install the bushing (7) on to the threaded end of
the valve housing (17).
E. Thread the nut (8) on to the valve housing (17).
Torque the nut to 30 in.lbs. / 3.4Nm.
5B
6A
6B
6C
6D
6E
6E