![Xpelair WX6EC - 071422 Installation And Maintenance Instructions Manual Download Page 6](http://html.mh-extra.com/html/xpelair/wx6ec-071422/wx6ec-071422_installation-and-maintenance-instructions-manual_888847006.webp)
operation of the switch, the delay ensures quiet
operation.
For Australia only:
WARNING
– Children should not play with the
appliance. Young children and the infirm should be
supervised
Trickle ventilation
Trickle ventilation is equivalent to that provided by an air
brick or similar device.
1. Remove the Inner grille and back draught shutter (see
‘Mounting the fan in the hole’ section).
To allow trickle ventilation:
2. HOLD THE SHUTTER VANES FULLY OPEN.
3. Push down firmly on the trickle vent catch until it clicks
into position then release the shutter vanes. (See Fig. G).
To fully close the shutters and stop any back draught
4. Pull the trickle vent catch towards you until it clicks into
position.
5.
Refit the Inner grille and back draught shutter,
ensuring that the actuator lever is in the “fully down”
position.
A QUALIFIED ELECTRICIAN MUST CARRY OUT ALL
CLEANING.
NOTE: THE FAN WILL CONTINUE TO OPERATE
WITH THE INNER GRILLE ASSEMBLY REMOVED,
HENCE IT MUST BE ISOLATED COMPLETELY FROM
THE MAINS BEFORE ANY WORK IS CARRIED OUT.
1.
Before cleaning, isolate the fan completely from
the mains supply. Allow 3 minutes for the impeller to
stop and the powered shutter to close.
2. Remove the inner grille and back-draught shutter by
removing the two screw covers and the screws securing
the inner grille assembly to the fan mounting box Fig. F
(10). To remove the backdraft shutter lay the inner grille
face down and pull shutter assembly upwards Fig. H1
and H2.
3.
To clean the impeller, wipe it with a damp, lint free
cloth.
Do not use strong detergents or chemical
cleaners.
4. Clean the back draught shutter, and inner grille by
immersing in warm soapy water. Dry thoroughly.
Do not immerse the fan in water or other liquids to
clean any other parts of the fan.
5. Refit the backdraft shutter Fig. H3 and H4.
6.
Refit the inner grille assembly and secure with the two
fixing screws.
Do not overtighten the screws.
7. Refit the screw covers.
• Never use strong solvents to clean the fan.
• Apart from cleaning, no other maintenance is
required.
Components
1. Inner Grille
2. Fan assembly
3. Outer Grille
4. Trickle vent catch
5. Wall Tube
6. Fan mounting box
7. Back draught shutter
8. Terminal cover
9. Rating Plate
10. Screws (M4 x 10mm long)
11. Worm Screws
12. Ladder Strips
10. Maintenance