OVEN OPERATOR CONTROLS
Software Version
MC, TC, & UI Software Version. Press Down arrow to go to next screen. Image For
Reference Only - See XLT For Correct Version.
Serial Number
ENTER button to make changes. Use side to side arrows to scroll to next character
position. Use Up/Down arrows to change values and press ENTER to accept and ad-
vance.
Elapsed Time
Elapsed time “Total Operation” and “Since Last Filter Cleaning”. Elapsed time total
cannot be reset. Press ENTER to advance.
Belt Length
There is currently only 36 belt length.
Belt Width
There is currently only 23 belt width.
Split Belt
MC1 is for left belt and MC2 is for right belt. Factory default is NO. To change press
ENTER. Use Up/Down arrows to change to YES (still flashing). Press ENTER to ac-
cept and advance.
Factory Tech Mode
To enter Factory Tech Mode press and hold the two (2) arrow buttons for ten (10) seconds.
TIP
Read and understand steps first. Screens will auto exit if no activity is sensed.
Remote Hood Switch
Factory default is NO. If there is a Remote Hood Switch installed, then press ENTER
and NO flashes. Use Up/Down arrows to change to YES. Press ENTER to accept and
advance.
Temp Offset Adjust
Factory default is zero. Allows the field tech to make adjustments up to +/- 20 degrees
in temperature.