V5 series inverter
87
The calculated length can be corrected through times of length (P9.10) and correction coefficient of length (P9.11), and the
corrected length is the actual length.
Actual length
=
calculated length
×
correction coefficient of length
÷
correcting coefficient of length
When actual length(P9.09)
≥
preset length(P9.08), the inverter will send out a STOP command to stop.When the inverter
restarts, it needs to clear the actual length (P9.09) or modify actual length (P9.09)< Reference length (P9.08), otherwise the
inverter will not start.
Note: (1)The actual length (terminal Xi is defined as function 36) can be cleared by multi-function input terminal. The
actual length can be calculated only after this terminal is disconnected.
(2) Actual length (P9.09) will be saved after power off automatically.
(3) Function of stopping at fixed length is disabled if P9.08 I set as 0, but the calculated length is still effective.
4-2-11
4-2-11
4-2-11
4-2-11.... Vector
Vector
Vector
Vector control
control
control
control parameters
parameters
parameters
parameters
(
Group
Group
Group
Group PA
PA
PA
PA
)
0
0
0
0
:
No
No
No
No turning
turning
turning
turning
1
1
1
1
:
Static
Static
Static
Static turning
turning
turning
turning
PA.01~PA.10 are set as motor parameters which have default setting dependent on inverter’s modle by the factory, you can
reset these parameters according to the motor parameters of yours. PA.01~PA.10 are used for vector control, which should
be input correctly so as to realize the expecting effect.
In vector control, this parameter is used to control torque current to avoid over current, 0~15 correspond to50%~200%.
PA.00
PA.00
PA.00
PA.00
Motor
Motor
Motor
Motor auto-turning
auto-turning
auto-turning
auto-turning
Range
Range
Range
Range
:
0
0
0
0,,,, 1
1
1
1
0
0
0
0
PA.01
PA.01
PA.01
PA.01
Rated
Rated
Rated
Rated voltage
voltage
voltage
voltage of
of
of
of motor
motor
motor
motor
Range
Range
Range
Range
:
0
0
0
0
~
400V
400V
400V
400V
Dependent
Dependent
Dependent
Dependent on
on
on
on
inverter
inverter
inverter
inverter’’’’ssss model
model
model
model
PA.02
PA.02
PA.02
PA.02
Rated
Rated
Rated
Rated current
current
current
current of
of
of
of motor
motor
motor
motor
Range
Range
Range
Range
:
0.01
0.01
0.01
0.01
~
500.00A
500.00A
500.00A
500.00A
Dependen
Dependen
Dependen
Dependentttt on
on
on
on
inverter
inverter
inverter
inverter’’’’ssss model
model
model
model
PA.03
PA.03
PA.03
PA.03
Rated
Rated
Rated
Rated frequency
frequency
frequency
frequency of
of
of
of motor
motor
motor
motor
Range
Range
Range
Range
:
1
1
1
1
~
99Hz
99Hz
99Hz
99Hz
Dependen
Dependen
Dependen
Dependentttt on
on
on
on
inverter
inverter
inverter
inverter’’’’ssss model
model
model
model
PA.04
PA.04
PA.04
PA.04
Rated
Rated
Rated
Rated speed
speed
speed
speed of
of
of
of motor
motor
motor
motor
Range
Range
Range
Range
:
1
1
1
1
~
9999
9999
9999
9999 r/min
r/min
r/min
r/min
Dependen
Dependen
Dependen
Dependentttt on
on
on
on
inverter
inverter
inverter
inverter’’’’ssss model
model
model
model
PA.05
PA.05
PA.05
PA.05
Polarity
Polarity
Polarity
Polarity of
of
of
of motor
motor
motor
motor
Range
Range
Range
Range
:
2
2
2
2
~
48
48
48
48
Dependen
Dependen
Dependen
Dependentttt on
on
on
on
inverter
inverter
inverter
inverter’’’’ssss model
model
model
model
PA.06
PA.06
PA.06
PA.06
Stator
Stator
Stator
Stator inductance
inductance
inductance
inductance of
of
of
of motor
motor
motor
motor
Range
Range
Range
Range
:
0.1
0.1
0.1
0.1
~
5000.0mH
5000.0mH
5000.0mH
5000.0mH
Dependen
Dependen
Dependen
Dependentttt on
on
on
on
inverter
inverter
inverter
inverter’’’’ssss model
model
model
model
PA.07
PA.07
PA.07
PA.07
Rotor
Rotor
Rotor
Rotor inductance
inductance
inductance
inductance of
of
of
of m
m
m
motor
otor
otor
otor
Range
Range
Range
Range
:
0.1
0.1
0.1
0.1
~
5000.0mH
5000.0mH
5000.0mH
5000.0mH
Dependen
Dependen
Dependen
Dependentttt on
on
on
on
inverter
inverter
inverter
inverter’’’’ssss model
model
model
model
PA.08
PA.08
PA.08
PA.08
Exciting
Exciting
Exciting
Exciting inductance
inductance
inductance
inductance of
of
of
of motor
motor
motor
motor
Range
Range
Range
Range
:
0.1
0.1
0.1
0.1
~
5000.0mH
5000.0mH
5000.0mH
5000.0mH
Dependen
Dependen
Dependen
Dependentttt on
on
on
on
inverter
inverter
inverter
inverter’’’’ssss model
model
model
model
PA.09
PA.09
PA.09
PA.09
Stator
Stator
Stator
Stator re
re
re
resis
sis
sis
sisttttance
ance
ance
ance of
of
of
of motor
motor
motor
motor
Range
Range
Range
Range
:
0.001
0.001
0.001
0.001
~
50.000
50.000
50.000
50.000
Ω
Dependen
Dependen
Dependen
Dependentttt on
on
on
on
inverter
inverter
inverter
inverter’’’’ssss model
model
model
model
PA.10
PA.10
PA.10
PA.10
Rotor
Rotor
Rotor
Rotor resistance
resistance
resistance
resistance of
of
of
of motor
motor
motor
motor
Range
Range
Range
Range
:
0.001
0.001
0.001
0.001
~
50.000
50.000
50.000
50.000
Ω
Dependen
Dependen
Dependen
Dependentttt on
on
on
on
inverter
inverter
inverter
inverter’’’’ssss model
model
model
model
PA.11
PA.11
PA.11
PA.11
Over
Over
Over
Over current
current
current
current protection
protection
protection
protection coefficient
coefficient
coefficient
coefficient of
of
of
of
torque
torque
torque
torque
Range
Range
Range
Range
:
0
0
0
0
~
15
15
15
15
15
15
15
15
PA.12
PA.12
PA.12
PA.12
Percentage
Percentage
Percentage
Percentage adjustment
adjustment
adjustment
adjustment coefficient
coefficient
coefficient
coefficient of
of
of
of speed
speed
speed
speed dev
dev
dev
dev
Range
Range
Range
Range
:
50
50
50
50
~
120
120
120
120
85
85
85
85
Summary of Contents for VB3-20P7
Page 59: ...V5 series inverter 53 ...