V5 series inverter
96
(2) The inverter is a master in the network, the slave will not response to the command sent by the inverter via broadcast
address.
(3) Users can set the inverter’s current address, baud rate and data format by using the inverter’s keypad or through the
serialcommunication port.
(4) The drive can report the current fault information when polled by the master.
7-2-
7-2-
7-2-
7-2-3
3
3
3.... Mode
Mode
Mode
Mode of
of
of
of communication
communication
communication
communication port
port
port
port
RS485, asynchronous, semi-duplex
Default: 1bit of start bit, 8 bits of data bit, 1 bit of stop bit, 9600bps. See Group P3.09
~
P3.12 for parameter settings.
7-3.Modbus-RTU
7-3.Modbus-RTU
7-3.Modbus-RTU
7-3.Modbus-RTU communication
communication
communication
communication protocol
protocol
protocol
protocol
7-
7-
7-
7-3
3
3
3----1
1
1
1.... Structure
Structure
Structure
Structure
7-
7-
7-
7-3
3
3
3----2
2
2
2.... Communication
Communication
Communication
Communication information
information
information
information
1
1
1
1.... RTU
RTU
RTU
RTU mode
mode
mode
mode
:
START
Keep the time no signal >=10ms
Address
Communication address
:
8-bit binary address
Function
Function code
:
8-bit binary address
DATA
(
n - 1
)
Data
:
N*8-bit data
,
N<=8
,
Max=8 bit
……………
DATA 0
CRC CHK Low
CRC verify code
CRC CHK High
16-bit CRC verify code is combined by 2 code of 8-bit binary
END
Keep the time no signal >=10ms