V5 series inverter
67
C:
C:
C:
C: Ten
Ten
Ten
Ten’’’’ssss place,
place,
place,
place, D:
D:
D:
D: Unit
Unit
Unit
Unit’’’’ssss place
place
place
place
P3.42 controls that if b-25
~
b-40 can be displayed in parameter group by four figures. The parameter values are in hex
which should be changed to binary ones according to the sequency of monitor parameters when using.The relationship
between four figures and parameters are shown in Fig. 4-17.
Fig.
Fig.
Fig.
Fig.4
4
4
4
-
17
17
17
17 Display
Display
Display
Display parameters
parameters
parameters
parameters selection
selection
selection
selection 2
2
2
2
((((R
R
R
Refer
efer
efer
efer to
to
to
to P73
P73
P73
P73 for
for
for
for b-09
b-09
b-09
b-09 ~
~
~
~ b-40
b-40
b-40
b-40))))
Note:
Note:
Note:
Note: A:
A:
A:
A: Thousand
Thousand
Thousand
Thousand’’’’ssss place,
place,
place,
place, B:
B:
B:
B: Hundred
Hundred
Hundred
Hundred’’’’ssss place,
place,
place,
place,
C:
C:
C:
C: Ten
Ten
Ten
Ten’’’’ssss place,
place,
place,
place, D:
D:
D:
D: Unit
Unit
Unit
Unit’’’’ssss place
place
place
place
Ten’s place, unit’s place
:
used to set stop status
Thousand’s place, hundred’s place
:
used to set running status
Example: When you want to let the inverter display current value in running status and display DC injucetion bus voltage
value, you can set P3.43=0304. You can also press the key
to view other monitor parameters.
P3.44
:
It is used to set proportion value between display value and output frequency of monitor parameter b-14.
Display
Display
Display
Display value
value
value
value of
of
of
of b
b
b
b----14
14
14
14=
=
=
=Output
Output
Output
Output frequency
frequency
frequency
frequency of
of
of
of inverter
inverter
inverter
inverter
×
P3.44
P3.44
P3.44
P3.44
P3.45 is used to select the usage of JOG/REV key in the panel
,
the references are shown below:
0
:
select to JOG
1
:
select to REV
4-2-5
4-2-5
4-2-5
4-2-5.... Function
Function
Function
Function parameters
parameters
parameters
parameters of
of
of
of terminal
terminal
terminal
terminal
(
Group
Group
Group
Group P4
P4
P4
P4
)
Multi-function input terminals X1~X8 support various functions which you can select freely to satisfy your
requirement. You can define the function of X1
~
X8 by setting the value of P4.00
~
P4.07, refer to Table 4-1 for
details, Among these terminals, X7 corresponds to FWD and X8 corresponds to REV.
Table
Table
Table
Table 4-1
4-1
4-1
4-1 Multi-function
Multi-function
Multi-function
Multi-function selection
selection
selection
selection
P3.42
P3.42
P3.42
P3.42
Display
Display
Display
Display parameters
parameters
parameters
parameters
selection
selection
selection
selection 2
2
2
2
Range
Range
Range
Range
:
00
00
00
0000
00
00
00
~
FFFF
FFFF
FFFF
FFFF
0000
0000
0000
0000
P3.43
P3.43
P3.43
P3.43
Display
Display
Display
Display parameters
parameters
parameters
parameters 3
3
3
3
Range
Range
Range
Range
:
0000
0000
0000
0000
~
4040
4040
4040
4040
0001
0001
0001
0001
P3.44
P3.44
P3.44
P3.44
Display
Display
Display
Display coefficient
coefficient
coefficient
coefficient without
without
without
without unit
unit
unit
unit
Range
Range
Range
Range
:
0.1
0.1
0.1
0.1
~
60.0
60.0
60.0
60.0
1.0
1.0
1.0
1.0
P3.45
P3.45
P3.45
P3.45
JOG/REV
JOG/REV
JOG/REV
JOG/REV shift
shift
shift
shift control
control
control
control mode
mode
mode
mode
Range
Range
Range
Range
:
0
0
0
0,,,,1
1
1
1
0
0
0
0
P4.00
P4.00
P4.00
P4.00
Function
Function
Function
Function selection
selection
selection
selection of
of
of
of input
input
input
input terminal
terminal
terminal
terminal X1
X1
X1
X1
Range
Range
Range
Range
:
0
0
0
0
~
37
37
37
37
1
1
1
1
P4.01
P4.01
P4.01
P4.01
Function
Function
Function
Function selection
selection
selection
selection of
of
of
of input
input
input
input terminal
terminal
terminal
terminal X
X
X
X2
2
2
2
Range
Range
Range
Range
:
0
0
0
0
~
37
37
37
37
2
2
2
2
P4.02
P4.02
P4.02
P4.02
Function
Function
Function
Function selection
selection
selection
selection of
of
of
of input
input
input
input terminal
terminal
terminal
terminal X
X
X
X3
3
3
3
Range
Range
Range
Range
:
0
0
0
0
~
37
37
37
37
3
3
3
3
P4.03
P4.03
P4.03
P4.03
Function
Function
Function
Function selection
selection
selection
selection of
of
of
of input
input
input
input terminal
terminal
terminal
terminal X
X
X
X4
4
4
4
Range
Range
Range
Range
:
0
0
0
0
~
37
37
37
37
10
10
10
10
P4.04
P4.04
P4.04
P4.04
Function
Function
Function
Function selection
selection
selection
selection of
of
of
of input
input
input
input terminal
terminal
terminal
terminal X
X
X
X5
5
5
5
Range
Range
Range
Range
:
0
0
0
0
~
37
37
37
37
17
17
17
17
P4.05
P4.05
P4.05
P4.05
Function
Function
Function
Function selection
selection
selection
selection of
of
of
of input
input
input
input terminal
terminal
terminal
terminal X
X
X
X6
6
6
6
Range
Range
Range
Range
:
0
0
0
0
~
37
37
37
37
18
18
18
18
P4.06
P4.06
P4.06
P4.06
Function
Function
Function
Function selection
selection
selection
selection of
of
of
of input
input
input
input terminal
terminal
terminal
terminal X
X
X
X7
7
7
7
Range
Range
Range
Range
:
0
0
0
0
~
37
37
37
37
0
0
0
0
P4.07
P4.07
P4.07
P4.07
Function
Function
Function
Function selection
selection
selection
selection of
of
of
of input
input
input
input terminal
terminal
terminal
terminal X
X
X
X8
8
8
8
Range
Range
Range
Range
:
0
0
0
0
~
37
37
37
37
0
0
0
0
Setting
Setting
Setting
Setting
Functions
Functions
Functions
Functions
Setting
Setting
Setting
Setting
Functions
Functions
Functions
Functions
b-25
~
b-28
b-29
~
b-32
b-33
~
b-36
b-37
~
b-40
A
B
C
D
Summary of Contents for VB3-20P7