V5 series inverter
62
DC injection braking current at start is a percentage value of inverter’s rated current. There is no DC injection braking when
the braking time is 0.00s.
Fig.
Fig.
Fig.
Fig.4-11
4-11
4-11
4-11 Starting
Starting
Starting
Starting mode
mode
mode
mode 1
1
1
1
Fig.
Fig.
Fig.
Fig. 4-12
4-12
4-12
4-12 Dec-to-stop
Dec-to-stop
Dec-to-stop
Dec-to-stop+
+
+
+DC
DC
DC
DC injection
injection
injection
injection braking
braking
braking
braking
0
0
0
0
:
Dec-to-stop
Dec-to-stop
Dec-to-stop
Dec-to-stop
After receiving the stopping command, the inverter reduces its output frequency within its Dec time and stops when the
frequency becomes 0.
1
1
1
1
:
Coast
Coast
Coast
Coast to
to
to
to stop
stop
stop
stop
After receiving the stopping command, the inverter stops output power immediately and the motor stops according to
mechanical inertia.
2
2
2
2
:
Dec-to-stop
Dec-to-stop
Dec-to-stop
Dec-to-stop
+
DC
DC
DC
DC injection
injection
injection
injection braking
braking
braking
braking
After receiving the stopping command, the inverter reduces its output frequency according to Dec time and then start to DC
injection braking after the output frequency reaching the initial frequency of braking at stop as in P2.06.
P2.08 refers to the set of DC injection braking current at stop which is the percentage value of inverter’s rated current.There
is no DC injection braking when the braking time is 0.0, as shown in Fig.4-12.
4-2-4
4-2-4
4-2-4
4-2-4.... Auxiliary
Auxiliary
Auxiliary
Auxiliary running
running
running
running parameters
parameters
parameters
parameters
(
Group
Group
Group
Group P3
P3
P3
P3
)
When P0.01
(
Frequency setting mode
)
is set to 8
,
combination of frequency setting can be set through this parameter.
0
:
VI
+
CI
1
:
VI
-
CI
2
:
External pulse reference
+
VI
+
Increase/Decrease key reference
3
:
External pulse reference
-
VI
-
Increase/Decrease key reference
4
:
External pulse reference
+
CI
5
:
External pulse reference
-
CI
6
:
RS485
+
VI+Increase/Decrease key reference
7
:
RS485
-
VI
-
Increase/Decrease key reference
8
:
RS485
+
CI+Increase/Decrease key reference
P2.05
P2.05
P2.05
P2.05
Stopping
Stopping
Stopping
Stopping mode
mode
mode
mode
Range
Range
Range
Range
:
0
0
0
0,,,,1
1
1
1,,,,2
2
2
2
0
0
0
0
P2.06
P2.06
P2.06
P2.06
DC
DC
DC
DC injection
injection
injection
injection braking
braking
braking
braking initial
initial
initial
initial frequency
frequency
frequency
frequency at
at
at
at
stop
stop
stop
stop
Range
Range
Range
Range
:
0.0
0.0
0.0
0.0
~
15.00Hz
15.00Hz
15.00Hz
15.00Hz
3.00Hz
3.00Hz
3.00Hz
3.00Hz
P2.07
P2.07
P2.07
P2.07
DC
DC
DC
DC injection
injection
injection
injection braking
braking
braking
braking time
time
time
time at
at
at
at stop
stop
stop
stop
Range
Range
Range
Range
:
0.0
0.0
0.0
0.0
~
60.0S
60.0S
60.0S
60.0S
0.0S
0.0S
0.0S
0.0S
P2.08
P2.08
P2.08
P2.08
injection
injection
injection
injection braking
braking
braking
braking current
current
current
current at
at
at
at stop
stop
stop
stop
Range
Range
Range
Range
:
0
0
0
0
~
80
80
80
80
(%)
0(
0(
0(
0(
%
))))
P3.00
P3.00
P3.00
P3.00
Combination
Combination
Combination
Combination of
of
of
of frequency
frequency
frequency
frequency setting
setting
setting
setting
Range
Range
Range
Range
:
0
0
0
0
~
20
20
20
20
0
0
0
0
Summary of Contents for VB3-20P7
Page 59: ...V5 series inverter 53 ...