V5 series inverter
72
Fig.
Fig.
Fig.
Fig. 4-23
4-23
4-23
4-23 3-wire
3-wire
3-wire
3-wire operation
operation
operation
operation mode
mode
mode
mode 1
1
1
1
Xi is the multi-function input terminal of X1~X6, here you should define its function as No.9 “3-wire control mode”.
3
3
3
3
:
3-wire
3-wire
3-wire
3-wire control
control
control
control mode
mode
mode
mode 2
2
2
2
SB1
:
Stop button
SB2
:
Running button
Fig.
Fig.
Fig.
Fig.4
4
4
4-24
-24
-24
-24
3-wire
3-wire
3-wire
3-wire control
control
control
control mode
mode
mode
mode 2
2
2
2
Xi is the multi-function input terminal of X1~X6
,
here you should define its function as No.9 “3-wire control mode”.
Note
Note
Note
Note
:
When the inverter stops due to fault, it will start immediately if the terminal control mode and terminal FWD/REV
are enabled and the fault is cleared.
This parameter defines the change rate of reference frequency that is changed by UP/DOWN.
Bi-direction oper-collector output terminal OC
,
the options of this parameter are shown in Table 4-6.
Table
Table
Table
Table 4-6
4-6
4-6
4-6 Functions
Functions
Functions
Functions of
of
of
of output
output
output
output terminals
terminals
terminals
terminals
P4.09
P4.09
P4.09
P4.09
UP/D
UP/D
UP/D
UP/DOW
OW
OW
OWN
N
N
N speed
speed
speed
speed rate
rate
rate
rate
Range
Range
Range
Range
:
0.01
0.01
0.01
0.01
~
99.99H
99.99H
99.99H
99.99Hz/s
z/s
z/s
z/s
1.00
1.00
1.00
1.00 H
H
H
Hz/
z/
z/
z/ssss
P4.10
P4.10
P4.10
P4.10
Bi-direction
Bi-direction
Bi-direction
Bi-direction open-collector
open-collector
open-collector
open-collector output
output
output
output terminal
terminal
terminal
terminal OC
OC
OC
OC
Range
Range
Range
Range
:
0
0
0
0
~
20
20
20
20
0
0
0
0
P4.11
P4.11
P4.11
P4.11
Relay
Relay
Relay
Relay output
output
output
output selector
selector
selector
selector
Range
Range
Range
Range
:
0
0
0
0
~
20
20
20
20
15
15
15
15
Setting
Setting
Setting
Setting
Functions
Functions
Functions
Functions
Setting
Setting
Setting
Setting
Functions
Functions
Functions
Functions
0
Inverter running (RUN)
11
PLC is finished after one cycle running
1
Frequency arriving signal(FAR)
12
Specified counting value arriving
2
Frequency detection threshold (FDT1)
13
Mid counting value arriving
3
Frequency detection threshold (FDT2)
14
Inverter Ready running finished
(
RDY
)
4
Overload pre-alarm
(
OL
)
15
Inverter fault
5
Inverter under voltage locking
(
LU
)
16
Start frenquence running time
6
External fault stop
(
EXT
)
17
Start DC injection braking time
Summary of Contents for VB3-20P7
Page 59: ...V5 series inverter 53 ...