82
7
52
/Custom Output 1 Output Port
Settings
-
0
※
2
○
All
53
/Custom Output 2 Output Port
Settings
-
0
※
2
○
All
57
PREFA segment 1 internal position
-
0
※
1
√
5
58
PREFB segment 2 internal position
-
0
※
1
√
5
59
PREFC segment 3 internal position
-
0
※
1
√
5
62
Probe function 1
—
0
0005
○
63
Probe function 2
—
0
0006
○
P6: signal parameters (some parameters are reserved)
P6-
Name
Unit Defa
ult
value
Range
Effec
tive
Suita
ble
mode
05
Speed loop gain in adaptive large inertia
mode
-
200
1-65535
●
All
07
Load inertia ratio in adaptive large
inertia mode
-
50
0-10000
●
All
08
Position loop gain in adaptive large
inertia mode
-
40
1-10000
●
All
12
Stable max inertia ratio in adaptive large
inertia mode
-
50
1-10000
●
All
Summary of Contents for DS5C Series
Page 3: ......
Page 4: ......
Page 13: ...5 1 2 Servo motor 1 2 1 Part description Encoder part Frame Flange Output transmission shaft...
Page 30: ...22 DS5C 20P7 PTA 60 0 183 0 181 3 48 8 172 0 5 5 5 5 182 9...
Page 54: ...46...