96
e
(220V:
U0-05
≥
390 alarm,
380V:
U0-05
≥
780V
alarm)
2. not connect
regenerative
resistor
3. regenerative
damaged
or
resistor too large
2. connect regenerative
resistor
3.
check
if
the
regenerative
resistor
matched power
390 alarm,
380V: U0-05
≥
780V alarm)
04
0
Bus
undervolta
ge(220V:
U0-05
≤
140.
380V:
U0-05
≤
300)
1. Power grid
voltage too low
2. instant power
off
1.
check
the
grid
fluctuation
2. use constant voltage
source
Bus
undervoltage(22
0V:
U0-05
≤
140.
380V: U0-05
≤
300)
1
Drive
power off
Drive power cut
off
Check
the
power
supply
Drive power off
3
Bus
voltage
charging
failure
Hardware
damage
Please note if there is
relay ON/OFF sound
when drive power on
Bus
voltage
charging failure
06
0
E-060
Module
temperature too
high
1. long time running
with large load
2.
environment
temperature too high
3. fan has error
1.
consider
change
the
motor
capacity(mointor
U0-02,
motor
present torque)