Key Name
Function
STATUS/ESC
Press: Status switch, status return
INC
Press: Increase the value; Press and hold: Increase the value continuously
DEC
Press: Decrease the value; Press and hold: Decrease the value continuously
ENTER
Press: Shift the editing digit; Press and hold: Enter a status, Enter
The operate panel can display the status, set parameter and run the command by switching the
basic mode.
The running status, auxiliary function, parameter setting, and monitoring are the basic modes.
The modes switch as the below diagram by pressing STATUS/ESC.
Status: bb indicates that the servo system is idle; Run indicates that the servo system is
running, and RST indicates that the servo needs to be powered on again.
P0-00
State
Parameter
Monitor
Alarm
Auxiliary
U0-00
F0-00
E-XXX
bb
run
Code
U1-00
Alarm
code
U2-00
Run
Idle
Speed
P1-00
P7-00
F1-00
Jog
Function
Control
Communication Power on
time
STA/ESC
INC
DEC
rst
Reset