![Xinje DS5B Series Manual Download Page 72](http://html1.mh-extra.com/html/xinje/ds5b-series/ds5b-series_manual_3494076072.webp)
keep inertia running state after
stop
28
Servo over range stop mode
0: deceleration stop, over range
direction torque is 0 after stop,
receive command
1: inertia stop, over range
direction torque is 0 after stop,
receive command
2: deceleration stop, over range
direction not receive command
after stop
3: alarm (E-260)
-
0
0~3
○
All
29
Servo alarm stop mode
0: inertia stop, keep inertia
running state after stop
2: deceleration stop, keep
inertia running state after stop
-
0
0
、
2
○
All
30
Stop overtime time
0.1m
s
2000
0~6553
5
○
All
33
Motor code
-
0~6553
5
●
All
69
Fan switch
0: temperature over 45º
C, fan is
ON, below 42º
C, fan is OFF
(hysteresis 3
℃
)
1: fan is ON after servo
enabled, fan is OFF after servo
is disable
1
0/1
○
All