![Xinje DS5B Series Manual Download Page 32](http://html1.mh-extra.com/html/xinje/ds5b-series/ds5b-series_manual_3494076032.webp)
R
S
T
.
U
V
W
P+
D
C
DS5B-21P5-PTA
、
DS5B-22P3-PTA
、
DS5B-41P5-PTA
Terminal
Function
Explanation
R/S/T
Power supply input
of main circuit
DS5B-21P5/22P3-PTA
:
3-phase AC200~240V, 50/60Hz
DS5B-41P5-PTA
:
3-phase AC360~400V, 50/60Hz
●
Vacant
-
U
、
V
、
W
Motor terminals
Connect the motor
(Note: the ground line is on the
cooling fin, please check it before
power on!)
P+
、
D
、
C
Internal
regenerative resistor
Short P+ and D, disconnect P+ and C,
set P0-24=0
External
regenerative resistor
Connect regenerative resistor between
P+ and C, disconnect P+ and D, set
P0-24=1, P0-25= power value, P0-26=
resistor value
Ground
Connect to ground terminal of motor,
then connect to the ground