General Procedures / Information
6-72
12/04
FaxCentre F110
Line control
EXT_LOOP:
Loop current input signal. This signal is used to indicate that a loop current is drawn by an external
phone (if Off-Hook).
External loop current status (EXT_LOOP) also changes if Ringer applied Par-
allel Phone state changes
The loop detection detects the current that flows in the external parallel phone. The detection
should bi-directional and work from 5mA to 100mA without disturbing the external phone.
INT_LOOP:
Internal loop detected. This signal is used to check the voltage in the LIU.
The voltage is measured just after the rectifier bridge. The threshold level can be adjusted by
R817 and R818. The transistor Q805 then drives the optocoupler Z801.
External loop current status (EXT_LOOP) also changes if
PD changes
Ringer applied
Parallel Phone state changes
Line polarity reversal
Flash key dialled
The two signals EXT_LOOP and INT_LOOP are then used by the firmware to decide whether or
not switch the relay.
Table 2:
EXT_LOOP
State
0
Loop current, external Phone
Off-Hook
1
Default
, no loop current
Table 3:
INT_LOOP
State
0
Default
, Off Hook or line disconnected
(LIU_HOOK=0)
1
Line connected(LIU_HOOK=1) and On Hook
Summary of Contents for FaxCentre F110
Page 1: ...12 04 FaxCentre F110 SERVICE MANUAL ...
Page 4: ...Introduction ii 12 04 FaxCentre F110 Page intentionally blank ...
Page 10: ...Service Call Procedures 1 2 12 04 FaxCentre F110 Page intentionally blank ...
Page 14: ...Status Indicator RAPs 2 2 12 04 FaxCentre F110 Page intentionally blank ...
Page 40: ...Image Quality 3 2 12 04 FaxCentre F110 Page intentionally blank ...
Page 56: ...Repairs Adjustments 4 2 12 04 FaxCentre F110 Page intentionally blank ...
Page 72: ...Repairs Adjustments 4 18 12 04 FaxCentre F110 Page intentionally blank ...
Page 74: ...Spare Parts List 5 2 12 04 FaxCentre F110 Page intentionally blank ...
Page 137: ...General Procedures Information FaxCentre F110 12 04 6 51 GP 17 18 Not Used ...
Page 190: ...General Procedures Information 6 104 12 04 FaxCentre F110 Page intentionally blank ...
Page 192: ...Wiring Diagrams 7 2 12 04 FaxCentre F110 Page intentionally blank ...
Page 198: ...Wiring Diagrams 7 8 12 04 FaxCentre F110 WD 6 Wiring Diagram Figure 1 ...
Page 200: ...Page intentionally blank ...
Page 202: ...XEROX EUROPE ...