General Procedures / Information
FaxCentre F110
12/04
6-65
GP 30 LED Management
The signal VLED of the CIS is connected to the 24V. The signal GLED is switched on and off by
a port of a ULN2003 (Z202). Three resistor in parallel limits the current to the requested value.
For the 200DPI CIS, the characteristics are:
•
92mA
•
Forward voltage of the LED: 13.5V-15V (for 35mA)
Set to 92mA for 200DPI CIS. The source is switched on/off by the signal LED_G. The minimum
forward voltage is 17.4V, the maximum
18.9V
, so the source current should withstand a Vce be-
tween
xxxV
and
xxxV
, and a maximum power of
1W
.
Summary of Contents for FaxCentre F110
Page 1: ...12 04 FaxCentre F110 SERVICE MANUAL ...
Page 4: ...Introduction ii 12 04 FaxCentre F110 Page intentionally blank ...
Page 10: ...Service Call Procedures 1 2 12 04 FaxCentre F110 Page intentionally blank ...
Page 14: ...Status Indicator RAPs 2 2 12 04 FaxCentre F110 Page intentionally blank ...
Page 40: ...Image Quality 3 2 12 04 FaxCentre F110 Page intentionally blank ...
Page 56: ...Repairs Adjustments 4 2 12 04 FaxCentre F110 Page intentionally blank ...
Page 72: ...Repairs Adjustments 4 18 12 04 FaxCentre F110 Page intentionally blank ...
Page 74: ...Spare Parts List 5 2 12 04 FaxCentre F110 Page intentionally blank ...
Page 137: ...General Procedures Information FaxCentre F110 12 04 6 51 GP 17 18 Not Used ...
Page 190: ...General Procedures Information 6 104 12 04 FaxCentre F110 Page intentionally blank ...
Page 192: ...Wiring Diagrams 7 2 12 04 FaxCentre F110 Page intentionally blank ...
Page 198: ...Wiring Diagrams 7 8 12 04 FaxCentre F110 WD 6 Wiring Diagram Figure 1 ...
Page 200: ...Page intentionally blank ...
Page 202: ...XEROX EUROPE ...