General Procedures / Information
6-34
12/04
FaxCentre F110
LED (Test-Code 111)
The LED’s are switched on and off in cycles of 0,5sec.
The assessment of the LED is visually made by the Technician. According to the assessment the
Technician presses the standard buttons for OK/NOK. The input is possible only after a time of
0.5 sec.
Flow:
Pass:
All Tests ok, no anomaly occurred.
Resultbytes:
00 ... Test ok
FF ... Test not done
80 … Operator pressed <STOP>
Table 1:
Step
Status
Operator
UUT
Display
Remarks
1
Is in Testmode and wait for
command
YYY TESTMODE XX YYY…last Testcode
XX…Errorcode or 00
2
Enter Command
Keypad: 111
3
Set/clear LED after each
other
LED TEST
4
OK
Press <START>
Set Resultbyte to 00
111 TESTMODE XX XX = 00 and no anom-
aly occurred
5
NOK
Press <STOP>
Set Resultbyte to XX
111 TESTMODE XX XX <> 00 or anomaly
occurred
Summary of Contents for FaxCentre F110
Page 1: ...12 04 FaxCentre F110 SERVICE MANUAL ...
Page 4: ...Introduction ii 12 04 FaxCentre F110 Page intentionally blank ...
Page 10: ...Service Call Procedures 1 2 12 04 FaxCentre F110 Page intentionally blank ...
Page 14: ...Status Indicator RAPs 2 2 12 04 FaxCentre F110 Page intentionally blank ...
Page 40: ...Image Quality 3 2 12 04 FaxCentre F110 Page intentionally blank ...
Page 56: ...Repairs Adjustments 4 2 12 04 FaxCentre F110 Page intentionally blank ...
Page 72: ...Repairs Adjustments 4 18 12 04 FaxCentre F110 Page intentionally blank ...
Page 74: ...Spare Parts List 5 2 12 04 FaxCentre F110 Page intentionally blank ...
Page 137: ...General Procedures Information FaxCentre F110 12 04 6 51 GP 17 18 Not Used ...
Page 190: ...General Procedures Information 6 104 12 04 FaxCentre F110 Page intentionally blank ...
Page 192: ...Wiring Diagrams 7 2 12 04 FaxCentre F110 Page intentionally blank ...
Page 198: ...Wiring Diagrams 7 8 12 04 FaxCentre F110 WD 6 Wiring Diagram Figure 1 ...
Page 200: ...Page intentionally blank ...
Page 202: ...XEROX EUROPE ...