2/99
GENERAL PROCEDURES
DocuPrint C55/C55mp/[NC60]
6-9
SPECIAL DIAGNOSTICS
ID LEVEL
This Diagnostic routine is used to set the
image density.
1. Enter Special diagnostics and press the
Menu [3]
key until
ID LEVEL YELLOW
is
displayed on the Message Display.
2. Press the
Next [6]
/
Previous [5]
keys until
the Message Display steps to the color
density to be changed (Table 5).
3. Press the
Enter [7]
key the display will
indicate:
XXXX ###
XXXX is the color name.
###
is the current density value.
4. Press the
Next [6]
/
Previous [5]
keys to
change the density value.
5. To store the density change insert a sheet
of paper into the bypass slot to actuate the
Bypass Switch, then press the
Form Feed
[1]
key
.
The On Line LED will switch on
and then off when the change is stored.
6. stored.
7. Press the
Media Server [2]
key to return
the ID LEVEL list. Repeat steps 2 through
5 to change additional densities.
NOTE: This value is changed when setting the
color density and color balance.
TIMEOUT SET
This Diagnostic routine is used to set when the
printer enters the Power Saver (Sleep) mode.
It is also used to set when the Polygon motor
shuts off.
1. Enter Special diagnostics and press the
Menu [3]
key until
TIMEOUT SET SLP
is
displayed on the Message Display.
2. Press the
Next [6]
/
Previous [5]
keys until
the Message Display steps to the timeout
to be changed (Table 6).
3. Press the
Enter [7]
key the display will
indicate:
XXX ###
XXX is the timeout feature to be
changed.
###
is the current timeout value.
4. Press the
Next [6]
/
Previous [5]
keys to
change the timeout value.
5. To store the change insert a sheet of paper
into the bypass slot to actuate the Bypass
Switch, then press the
Form Feed [1]
key
.
The On Line LED will switch on and then
off when the change is stored.
6. Press the
Media Server [2]
key to return
to the TIMEOUT SET list. Repeat steps 2
through 5 to change the other timeout
value.
PANEL KEY TEST
This Diagnostic routine is check the operation
of the switches on the control panel.
1. Enter Special diagnostics and press the
Menu [3]
key until
PANEL KEY TEST
is
displayed on the Message Display.
2. Actuate the Bypass Switch, then press the
Form Feed [1]
key. The display will
indicate:
1?2?3?4?5?6?7?8?
3. Refer to Table 7 for the number assigned
to the key. When the key is pressed, the ?
will change to a
←
.
Table 7
Key
Number
Key
Number
On Line [0]
1
Select [4]
5
Form Feed [1]
2
Previous [5]
6
Media Server
[2]
3
Next [6]
7
Menu [3]
4
Enter [7]
8
4. If all keys check OK, the display will
indicate:
1
←
2
←
3
←
4
←
5
←
6
←
7
←
8
←
5. Once all keys are checked the display will
show the DATE and then return to PANEL
KEY TEST.
Summary of Contents for DocuPrint C55
Page 14: ...SERVICE CALL PROCEDURES 2 99 NOTES 1 6 DocuPrint C55 C55mp NC60 Notes ...
Page 56: ...OTHER FAULTS RAPs 2 99 NOTES 2 42 DocuPrint C55 C55mp NC60 NOTES ...
Page 76: ...IMAGE QUALITY SPECIFICATIONS 2 99 NOTES 3 20 DocuPrint C55 C55mp NC60 NOTES ...
Page 130: ...REPAIRS ADJUSTMENTS 2 99 NOTES 4 42 DocuPrint C55 C55mp NC60 NOTES ...
Page 216: ...GENERAL PROCEDURES 2 99 NOTES 6 18 DocuPrint C55 C55mp NC60 Notes ...
Page 252: ...GENERAL PROCEDURES 2 99 NOTES 6 54 DocuPrint C55 C55mp NC60 NOTES ...
Page 272: ...GENERAL PROCEDURES 2 99 NOTES 6 74 DocuPrint C55 C55mp NOTES ...
Page 274: ...GENERAL PROCEDURES 2 99 NOTES 6 76 DocuPrint NC60 NOTES ...