REPAIRS/ADJUSTMENTS
2/99
ADJ 3.3
4-64
DocuPrint C55/C55mp/[NC60]
ADJ 3.3B INITIALIZING THE NVM
CAUTION
Do not continue with the initialization
procedure until you have determined the
Consumable Usage and Toner Concentration
values. Always start at the beginning of this
procedure (ADJ 3.3A). Once you have
determined the Consumable and Toner
Concentration values, continue with the
Initialization.
1. Enter Normal diagnostics (
Menu [3]
+
Enter
[7]
, Power On). Write down the IOT software
version.
2. Initialize the NVM.
a. Press
Menu [3]
to scroll to NV-RAM
INITIAL.
b. Insert a sheet of paper into the bypass
slot to actuate the Bypass Switch, then
press the
Form Feed [1]
key. The On
Line LED will switch on and then off
when the change is stored.
4. Enter the Consumable Usage.
a. Press
Menu [3]
to scroll to COUNTER
SET DRUM.
b. Press
Enter [7]
.
c. Use
Menu [3]
to step to the digit to be
changed. Use
Next [6]/Previous [5]
to
change the value.
d. Insert a sheet of paper into the bypass
slot to actuate the Bypass Switch, then
press the
Form Feed [1]
key. The On
Line LED will switch on and then off
when the change is stored.
e. Press
Previous [5]
to select the next
consumable to be entered.
f.
Repeat steps b through e until all
consumable values have been entered.
5. Enter the Page Counts.
a. Press
Menu [3]
to scroll to PCU DIAG
MODE.
b. Enter Special Diagnostics (PCU DIAG
MODE displayed, press
On Line [0]
,
then press
Enter [7]
, release both).
c. Use
Menu [3]
to scroll to COUNTER
SET2 TTL.
d. Press
Enter [7].
e. Use
Menu [3]
to step to the digit to be
changed. Use
Next [6]/Previous [5]
to
change the value.
f.
Insert a sheet of paper into the bypass
slot to actuate the Bypass Switch, then
press the
Form Feed [1]
key. The On
Line LED will switch on and then off
when the change is stored.
g. Press
Previous [5]
to select the next
Page Count to be entered.
h. Repeat steps d through g until all Page
Counts have been reentered.
6. Enter the Toner Concentration Setpoints.
a. Press
Media Server [2]
then use
Menu
[3]
to scroll to TONER LEVEL YTON.
b. Press
Enter [7].
c. Use
Next [6]/Previous [5]
to change the
value.
d. Insert a sheet of paper into the bypass
slot to actuate the Bypass Switch, then
press the
Form Feed [1]
key. The On
Line LED will switch on and then off
when the change is stored.
e. Use
Previous [5]
to step to the next
setpoint to be changed.
f.
Repeat steps b through e until all four
Toner Concentration setpoints have
been stored.
7. If the IOT software level is version 66, go
Section 6 in the service manual and perform
the Fuser Speed adjustment (GP 3.1).
8. Exit from Diagnostics by switching the power
off waiting 10 seconds and switching the
power back on.
Summary of Contents for DocuPrint C55
Page 14: ...SERVICE CALL PROCEDURES 2 99 NOTES 1 6 DocuPrint C55 C55mp NC60 Notes ...
Page 56: ...OTHER FAULTS RAPs 2 99 NOTES 2 42 DocuPrint C55 C55mp NC60 NOTES ...
Page 76: ...IMAGE QUALITY SPECIFICATIONS 2 99 NOTES 3 20 DocuPrint C55 C55mp NC60 NOTES ...
Page 130: ...REPAIRS ADJUSTMENTS 2 99 NOTES 4 42 DocuPrint C55 C55mp NC60 NOTES ...
Page 216: ...GENERAL PROCEDURES 2 99 NOTES 6 18 DocuPrint C55 C55mp NC60 Notes ...
Page 252: ...GENERAL PROCEDURES 2 99 NOTES 6 54 DocuPrint C55 C55mp NC60 NOTES ...
Page 272: ...GENERAL PROCEDURES 2 99 NOTES 6 74 DocuPrint C55 C55mp NOTES ...
Page 274: ...GENERAL PROCEDURES 2 99 NOTES 6 76 DocuPrint NC60 NOTES ...