12Vdc system
24Vdc system
200Amp.
100Amp.
500Amp. (1sec.)
250Amp. (1sec.)
PIN 30 of 87
≥
13,2Vdc for 10sec.
PIN 30 of 87
≥
26,4Vdc for 10sec.
PIN 30 of 87
≥
13,8Vdc for 2sec.
PIN 30 of 87
≥
27,6Vdc for 2sec.
PIN 30 of 87
≤
12,8Vdc for 60sec.
PIN 30 of 87
≤
25,6Vdc for 60sec.
PIN 30 of 87
≤
12,5Vdc for 30sec.
PIN 30 of 87
≤
25,0Vdc for 30sec.
PIN 30 of 87
≤
12,0Vdc for 5sec.
PIN 30 of 87
≤
24,0Vdc for 5sec.
PIN 30 of 87
≤
11,0Vdc for 0sec.
PIN 30 of 87
≤
22,0Vdc for 0sec.
200mA @ 13,5Vdc
135mA @ 27Vdc
* = based on 20
⁰
C
** = if mounted according to the instructions
Data subject to changes
Number of batteries
2
SR 200-12/24
System voltage
12 and 24Vdc, auto detect
Inputvoltage range
8-35Vdc
Ambient temperature
-30°C ~ 60°C
Max. current*
Max surge current*
Connect details (closed)
±
2%
Disconnect details (open)
±
2%
Consumption in closed condition
Consumption in open condition
5mA
Start assist function
Yes,
≥
30 seconds
Terminal connections
2x M6 bolts + 2x faston (6,3x0,8mm)
Level of protection**
IP 54
Weight
100gr.
Housing dimensions
4,8 x 4,6/7,8 x 4,6 cm