Installation and Setup
2-17
PMC Host Connector 2
Table 2-202 XVME 689-VR7 PMC Host Connector 2 Pin out
Pin
Signal
Pin
Signal
1
+12V
33
GND
2
TRST*
34
PMC-RSVD_PN2-34
3
TMS
35
TRDY*
4
TDO
36
+3.3V
5
TDI
37
GND
6
GND
38
STOP*
7
GND
39
PERR*
8
PCI-RSVD9A
40
GND
9
PCI-RSVD10B
41
+3.3V
10
PCI-RSVD11A
42
SERR*
11
BUSMODE2* (V_IO)
43
C_BE*(1)
12
+3.3V
44
GND
13
RST*
45
AD(14)
14
BUSMODE3* (GND)
46
AD(13)
15
+3.3V
47
GND
16
BUSMODE4* (GND)
48
AD(10)
17
PCI-RSVD19A
49
AD(8)
18
GND
50
+3.3V
19
AD(30)
51
AD(7)
20
AD(29)
52
PMC-RSVD_PN2-52
21
GND
53
+3.3V
22
PAD(26)
54
PMC-RSVD_PN2-54
23
PAD(24)
55
NC
24
+3.3V
56
GND
25
IDSEL*
57
NC
26
AD(23)
58
NC
27
+3.3V
59
GND
28
AD(20)
60
NC
29
AD(18)
61
ACK64*
30
GND
62
+3.3V
31
AD(16)
63
GND
32
CE_BE*(2)
64
RES (NC)
CPU Fan Power Connector
The fan +12 V and +5 V supplies are protected with a polyswitch. This device will open up if
+12 V or +5 V is shorted to GND. Once the shorting condition is removed, the polyswitch will
allow current flow to resume.
Table 2-21 CPU Fan Power Connector Pin out
Pin
Signal
1
GND
2
+12V (fused)
3
+5V pullup
Summary of Contents for XVME-689-VR7