background image

Basic Access Control with an i-touch

TM

 and Autocloser

TM

 

Wiring Instructions

 

*    Drawing is for reference only. Installation must follow local building and  
     electrical codes.  
*    For information regarding installation and setup of 

Autocloser

™, see  

     

Autocloser

™ manual.

 

For Solytech 
Model AD0509C 9VDC 
Adapter shown at left: 
Striped wire is negative. 
Solid wire is positive. 

*** 

WARNING ***

 

Be sure to connect the 
positive wire from the 
9VDC adapter to the red 
wire from the i-touch unit 
and connect the negative 
wire from the 9VDC 
adapter to the black wire 
from the i-touch. 
See above for adapter types 
and polarity indication. 

For Model GEO061U-1205 
9VDC Adapter shown at right: 
Striped wire is positive. 
Solid wire is negative. 
Note: This adapter has a blue 
power indicator LED. 

Summary of Contents for i-touch

Page 1: ...1 INSTALLATION MANUAL AND USER S GUIDE THIS MANUAL FOR USE WITH AUTOCLOSER ONLY Revision 1 5 Patent Pending ...

Page 2: ...at interference will not occur in a particular installation If this equipment does cause harmful interference to radio or tele vision reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following meas ures Reorient or relocate the receiving antenna Increase the separation between the equipment and rec...

Page 3: ... spools of 2 conductor wire 4 1 resealable bag holding 2 6 x 3 4 wood screws with wall anchors 1 set screw and 2 extra screws for Autocloser GA terminals 5 1 i touch mounting bracket 6 1 i touch Autocloser manual 7 4 Wiring splicing connectors i touch kit recommended additional components 1 If i touch is to be installed in plaster based wall without gang box consider using wall anchors for the scr...

Page 4: ...t through center of bracket and into wall hole Fig 3 5 Slide i touch unit onto mounting bracket Secure at bottom with setscrew 6 Connect wires per Wiring Instructions Fig 4 on the following page Mounting to wall with existing gang box 1 Remove plastic faceplate from standard single gang box Keep these screws in hand 2 Using screws from step 1 screw mounting plate into gang box 3 Thread cable from ...

Page 5: ...AD0509C 9VDC Adapter shown at left Striped wire is negative Solid wire is positive WARNING Be sure to connect the positive wire from the 9VDC adapter to the red wire from the i touch unit and connect the negative wire from the 9VDC adapter to the black wire from the i touch See above for adapter types and polarity indication For Model GEO061U 1205 9VDC Adapter shown at right Striped wire is positi...

Page 6: ...ing new users 2 Regardless of whether a Master Fingerprint or Master Code was chosen up to 29 additional fingerprints and up to 29 additional codes can be stored While the fingerprints are mated to a specific user s finger the codes can be linked to either a specific user or to a group of users For instance i Permanent fingerprint of a user is established so the user always can enter a secured are...

Page 7: ... ID that fingerprint in order to remove it from the system Alter natively the master wouldn t need to remove all the fingerprints from the i touch Autocloser 5 If a code is to be deleted the master must know that code Otherwise to remove it the master would need to remove all the codes from the i touch Autocloser kit and have only the desired people once again add their code 6 It helps keep track ...

Page 8: ...ip rests against the plastic stop See Tips and Tricks While the fingerprint matching process of the i touch is tolerant to non optimum finger placement centering the core just above the swirl section of the fingerprint will give the best possible performance See Fig 5 and Fig 6 Fig 6 The fingerprint core generally lines up under the beginning of the nail or about midway between the first knuckle a...

Page 9: ...odes are now erased and the unit is prepared to accept a MC or MF If ERROR LED is flashing verify step 2 HINT setup code 92358766 is the first 8 characters of Xceltronix as seen on a touch tone phone keypad 6 If a MC is preferred skip to step 7 To input a MF wait until the INPUT LED begins to blink No keys should be pressed before the INPUT LED begins flashing The Master User should place their fi...

Page 10: ...y 3 Input MF or input MC and the ENTER key If the Master User authoriza tion was successful the ACCEPT LED will flash 4 The ACCEPT LED will remain lit until all data has been transmitted This may take up to two minutes and there will be a series of beeps If the transmission is completed successfully the ACCEPT LED will flash Oth erwise the ERROR LED will flash and the procedure must be repeated 5 ...

Page 11: ...key If the MF or MC is accepted the ACCEPT LED will flash If the ACCEPT LED did not flash it either means the Master User wasn t recognized or that the maximum number of finger prints have already been added and the ERROR LED will flash 3 The INPUT LED should be flashing The new user should place their fin ger on the sensor and remove it when the INPUT LED stops flashing This fingerprint placement...

Page 12: ... number 1 To delete a fingerprint 1 Press the FUNC key then the 3 DELETE PRINT key 2 Input MF or input MC and the ENTER key 3 If the Master User authorization is accepted the ACCEPT LED will flash followed by a solid INPUT LED 4 Enter the ID of the fingerprint to be deleted followed by the ENTER key If the ID is a single digit 2 9 then a leading zero may be entered but is not required NOTE MF can ...

Page 13: ...n A Temporary Access Code is set to expire after a user specified number of days To input a temporary access code 1 Press the FUNC key then the 7 TEMPORARY key followed by the 4 ADD CODE key 2 Input MF or input MC and the ENTER key If the Master User Authoriza tion is successful the ACCEPT LED will flash 3 The INPUT LED should be lit solid Enter a 4 6 digit temporary access code followed by the EN...

Page 14: ...CEPT LED will flash 6 If finished with the batch of code additions perform i touch Auto closer synchronization procedure NOTE Users can add their code s into the table in the back of this manual Deleting A Temporary Or Permanent Access Code Requires Master User authorization 1 Press the FUNC key then the 8 DEL CODE key 2 Input MF or input MC and the ENTER key If the Master User Authoriza tion is s...

Page 15: ... If the fingerprint is accepted then the ACCEPT LED will flash The garage door will behave as if the existing garage door opener button were pressed If no fingerprint match is found the ERROR LED will flash Note Sometimes multiple fingerprint reading attempts are necessary to maintain tight security 4 The ENTER key option is now activated and the 10 second timer has started counting down See Tips ...

Page 16: ...ely a fingerprint can be scanned repeatedly without waiting through the ERROR flash ing An i touch Autocloser synchronization procedure does not need to be performed after each individual fingerprint code addition deletion but instead can be done after a batch of changes For the changes to take place and the new access permissions to be allowed denied the master must first perform i touch Autoclos...

Page 17: ...17 USER ID PERM or TEMP ENTRY DATE DURATION FINGERPRINT USER S NAME 1 MASTER USER 2 3 4 5 6 7 8 9 10 11 12 13 14 15 ...

Page 18: ...18 USER ID PERM or TEMP ENTRY DATE DURATION FINGERPRINT USER S NAME 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 ...

Page 19: ...19 PERM or TEMP ENTRY DATE DURATION CODE USER GROUP NAME CODE 1 MASTER USER 2 3 4 5 6 7 8 9 10 11 12 13 14 15 ...

Page 20: ...20 PERM or TEMP ENTRY DATE DURATION CODE USER GROUP NAME CODE 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 ...

Page 21: ...uch we may replace it with a new or reconditioned unit of the same or similar design During the first 90 days from the date of purchase all parts and labor are free of charge After the first 90 days from the date of purchase all parts are free and a nominal diagnosis charge will be collected for labor How is warranty service obtained We suggest that you retain your original pack ing materials in t...

Page 22: ...2 REPLACEMENT PARTS To order replacement parts visit our website at www autocloser com Or contact us Xceltronix Inc 1226 Exchange Drive Richardson TX 75081 1 877 748 8366 1 877 SHUT DOOR or 972 437 9393 ...

Page 23: ...23 Please mail to Xceltronix Inc 1226 Exchange Drive Richardson TX 75081 ...

Reviews: