XW Series Overload Capability
Loads presented to the inverter are seldom constant. Typically, large loads are operated for
only short periods of time. In order to provide the maximum utility, Xantrex inverters are
allowed to operate at power levels that exceed their continuous power ratings. This graph
shows how loads that are larger than the inverter can sustain continuously can be operated
for useful periods of time.
The length of time that the inverter can operate at high power is limited by temperature.
When large loads are run, the inverter’s temperature increases. At the point where more
heat is created in the inverter than can be dissipated, its ability to operate becomes time
limited.
DC Input Voltage Range
44–64 Vdc
44–64 Vdc
22–32 Vdc
DC Current at Rated Power
130 A
96 A
178 A
Continuous Charge Rate at L-L voltage
100 A
85 A
150 A
Power Factor Corrected Charging
PF (0.98)
a.This unit or system is provided with fixed trip limits and shall not be aggregated above 30 kW on a single Point of
Common Connection
Table A-1
XW Power System Electrical Specifications
Model
XW6048-120/240-60
XW4548-120/240-60
XW4024-120/240-60
Figure A-1
XW Series AC Overload Capability