![Xantrex XTR 850 Watt Operating Manual Download Page 236](http://html1.mh-extra.com/html/xantrex/xtr-850-watt/xtr-850-watt_operating-manual_3458198236.webp)
Calibration and Troubleshooting
B-2
M370046-01
Introduction
The calibration of the power supply is software dependent, and there are
no potentiometers to adjust.
Calibration is performed via SCPI commands.
The following items need to be calibrated:
•
Programmed voltage
•
Voltage readback
•
Programmed current
•
Current readback
•
Non-isolated voltage monitoring
•
Isolated voltage monitoring
•
Non-isolated current monitoring
•
Isolated current monitoring
•
Isolated source for analog programming
•
Non-isolated source for analog programming
•
Over voltage protection system
CAUTION: Equipment damage
Calibration procedures should only be performed by qualified user.