SCPI Command Reference
A-4
M370046-01
Using SCPI Commands
This Manual shows SCPI commands in the following format:
CALibration:CURRent:LEVel {<current>|MIN|MAX}
The command is expressed as a mixture of upper- and lowercase letters.
The uppercase letters suggest how the command can be abbreviated into a
short form. SCPI commands can be sent in long or short forms. The short
form is better for data entry. The long form is better for readability.
Command strings are not case sensitive:
CURR
,
Curr
, and
curr
are all
acceptable abbreviations for
CURRent
. As for the long form,
CURRENT
,
Current
, and
current
are all acceptable. It is not possible to write for
example,
CALibrat:CURR:LEV
because the extra first node does not
explicitly match the short or long form of the calibration node.
The command strings include punctuation. While some punctuation is
sent with the string, other markings are used to identify different elements
of the command syntax and are not sent with the string.
The following punctuation is sent with the command string:
•
Colons (:)
separate command keywords from lower-level keywords.
For example,
CAL:CURR:STAT
.
•
Blank spaces
separate command keywords from parameter values.
For example,
CURR 0.1
.
•
Commas
separate parameters from each other when more than one
parameter is sent in the same string. For example,
CAL:STAT
OFF,”1234.”
•
Semicolons (;)
separate multiple commands from the same
subsystem. This allows for greater efficiency.
For example: CAL:CURR:LEV MIN;VOLT:LEV MIN
is the same as typing:
CAL:CURR:LEV MIN
CAL:VOLT:LEV MIN
•
Colons and semicolons
can be used together to link commands from
different subsystems. For example:
CAL:CURR:LEV MIN;:MEAS:CURR?
The short form is made up of 3 or 4 letters. There can only be a
absolute short or long form. For example, it is not possible to write
CALibrat:CURR:LEV because the extra the first node does not match
explicitly the short or long form of the calibration node.
Summary of Contents for XTR 850 Watt
Page 2: ......
Page 3: ...XTR 850 Watt Series Programmable DC Power Supply firmware v1 09 and below Operating Manual...
Page 6: ......
Page 18: ...xvi...
Page 30: ...1 8...
Page 52: ...Local Operation 3 8 M370046 01 Figure 3 3 Front Panel Menu System...
Page 126: ...Analog Programming APG and Isolated Analog Programming ISOL 4 34 M370046 01...
Page 198: ...5 72...
Page 234: ...A 36...
Page 284: ...IX 4...
Page 285: ......