![Xantrex XTR 850 Watt Operating Manual Download Page 104](http://html1.mh-extra.com/html/xantrex/xtr-850-watt/xtr-850-watt_operating-manual_3458198104.webp)
Analog Programming (APG) and Isolated Analog Programming (ISOL)
4-12
M370046-01
Voltage-Controlled Current APG Setup
Activating APG Current Mode
To activate APG current mode using an external voltage source:
1. Turn the 9-position mode control to the CAP position or press the
rotary Adjust/Enter control if the mode control is already at the CAP
position.
CAPr
is displayed on the output voltage display.
2. Turn the rotary Adjust/Enter control to select source
Un1S
(Voltage
source from non-isolated connector).
3. Press the rotary Adjust/Enter control to commit the selected mode.
LE C
is displayed on the output voltage display.
4. Select the input source level using the rotary Adjust/Enter control.
5. Once the desired level has been selected, press the rotary Adjust/
Enter control to commit the change.
The display will return to the normal display.
Deactivating APG Current Mode
To deactivate the APG current mode:
1. Turn the 9-position mode control to the CAP position or press the
rotary Adjust/Enter control if the mode control is already at the CAP
position.
2.
CAPr
is displayed on the output voltage display.
3. Turn the rotary Adjust/Enter control to select
nonE
.
4. Press the rotary Adjust/Enter control to commit the change.
The display will return to the normal display.
Summary of Contents for XTR 850 Watt
Page 2: ......
Page 3: ...XTR 850 Watt Series Programmable DC Power Supply firmware v1 09 and below Operating Manual...
Page 6: ......
Page 18: ...xvi...
Page 30: ...1 8...
Page 52: ...Local Operation 3 8 M370046 01 Figure 3 3 Front Panel Menu System...
Page 126: ...Analog Programming APG and Isolated Analog Programming ISOL 4 34 M370046 01...
Page 198: ...5 72...
Page 234: ...A 36...
Page 284: ...IX 4...
Page 285: ......