Remote Operation
SCPI Commands for Digital Interfaces
124
Operating Manual for XDC Series Power Supply
Last Setting
Selecting
Last Setting
lets you restore the settings that are in use when the power
supply is powered off, the next time it is powered on.
To power on the last stored setting:
OUTP:PON:REC LAST
To check the current user setting:
OUTP:PON:REC?
The response should be
LAST
.
User Setting
Selecting
User Setting
lets you restore a custom setting next time the unit is powered
on. This assumes that at least one user setting has been set up and stored in memory.
See “Store User Settings” on page 77.
To power on user setting #1:
OUTP:PON:REC USER1
To check the setting:
OUTP:PON:REC?
The response should be
USER1
.
The user setting must be in the range of 1–10. See “Store User Settings” on page 127
for an explanation of how to save user settings.
Auto Sequence
Selecting
Auto Sequence
lets you recall a stored program next time the unit is
powered ON. This assumes that at least one program has been created and stored in
memory. See “Editing Trigger Source of a Sequence” on page 96 for more
information. See for information about remotely programming and running auto
sequence programs.
To reset to user setting #1:
OUTP:PON:REC SEQ1
To check the setting:
OUTP:PON:REC?
The response should be
SEQ1
.