Operation
Power Supply Operation
Release 3.0
83
Configure
User Lines
The USER LINES menu option lets you configure the auxiliary status lines
The Auxiliary (Aux) lines are 2 open collector outputs that can be used to monitor
the status of the power supply. The auxiliary lines are referred to as AUX A and
AUX B. See “Making Connections for Remote Control” on page 107 for details.
Each user line also has a corresponding annunciator on the front panel display to
indicate when it is on. Aux lines can be set up to report the following status
conditions:
•
None
•
Unregul:
Output Unregulated
•
OVP:
Over-Voltage Condition
•
UV:
Under-Voltage Condition
•
OC:
Over-Current Condition
•
UC:
Under-Current Condition
•
OP:
Over-Power Condition
•
UP:
Under-Power Condition
•
AC Off:
Input power has failed or is out of range
•
OTP:
Over-Temperature Condition
•
Hi Temp:
High-Temperature Condition
•
SenseProt:
Sense Protection Tripped
•
Fold Prot:
Fold Protection Tripped
•
CC:
Constant Current Mode
•
CV:
Constant Voltage Mode
•
CP:
Constant Power Mode
•
Out ON:
Output On
•
Out OFF:
Output Off
To access and work with the USER LINES menu option:
Step # Do This
You Will See
1
ERROR MSGS
2
1
1. You can also press
MENU
again to bring up the AUX LINES option.
USER LINES
3
Aux line A
4
or
to select which
line to configure.
Aux line B
5
Cfg None
MENU
ENTER
ENTER