Operating Manual for
XDC Series Power Sup
ply
SCPI Command Re
fe
rence
SCPI C
omman
d Summary
Table B.7
Commands for Fold Protection
Table B.8
Commands for Triggering
Table B.9
System Commands
Function
SCPI Command
Description
Query
Set Output Fold Delay
[:]OUTPut[<channel>]:PROTection:FOLD:DELay <delay>
Set the delay time (seconds) before fold
protection is triggered.
Yes
Set Output Fold Mode
[:]OUTPut[<channel>]:PROTection:FOLD[:MODE]
{NONE|CC|CP|CV}
Select which regulation mode to fold back
(None,CV, CC, CP)
Yes
Query Fold Protection
Tripped
[:]OUTPut[<channel>]:PROTection:FOLD:TRIPped?
Query if fold protection has tripped
N/A
Function
SCPI Command
Description
Query
Set Immediate Initiation of
Trigger System
[:]INITiate[<channel>][:IMMediate]
Initiate a triggered event or sequence
N/A
Set Trigger Source
[:]TRIGger[<channel>][:SEQuence]:SOURce
{BUS|EXTernal|IMMediate|NONE}
Sets the trigger source for triggered
setpoints
Yes
Function
SCPI Command
Description
Query
Query System Error
[:]SYSTem[<channel>]:ERRor[:NEXT]?
Returns the next error in the instrument’s
error queue
N/A
Recall Default Factory
Preset
[:]SYSTem[<channel>]:RECall:DEFault
Restore the factory preset values
N/A
Select Remote Control
Source
[:]SYSTem[<channel>]:REMote:SOURce
{RS232|GPIB|AVOLtage|ACURrent|AVCurrent|MCHannel}
Select the remote control source
Yes
Set RS-232 Baud Rate
[:]SYSTem[<channel>]:COMMunicate:SERial[:RECeive]:BAU
D {1200|2400|4800|9600|…}
Configure the RS-232 baud rate
Yes
Set RS-232 Flow Control
[:]SYSTem[<channel>]:COMMunicate:SERial[:RECeive]:PAC
E {HARDware|XON|NONE}
Select type of flow control for RS-232
Yes
Set Multichannel Address
(6000 W only)
[:]SYSTem[<channel>]:COMMunicate:MCHannel:ADDRess
<channel>
Select the multichannel unit address
Yes
Set GPIB Address
[:]SYSTem[<channel>]:COMMunicate:GPIB[:SELF]:ADDRess
<GPIB_address>
Configure GPIB address
Yes
Set GPIB Power On
Service Request
[:]SYSTem[<channel>]:COMMunicate:GPIB[:SELF]:PONSrq
{ON|OFF|0|1}
Configure GPIB PON SRQ
Yes
Select Range for Analog
Programming Interface
[:]SYSTem[<channel>]:COMMunicate:APRogram:LEVel
{5|10}
Select analog interface voltage levels
Yes
Set Remote Control
Operation (Serial
Interface)
[:]SYSTem[<channel>]:REMote:STATe
{LOCal|REMote|RWLock}
RS-232 Only. Change remote control mode
Yes
Query SCPI Version
[:]SYSTem[<channel>]:VERSion?
Returns the SCPI version to which the
instrument complies. Format is YYYY.V
N/A