975-0289-01-01
2–5
Batteries
The PowerHub will use the power stored in the batteries to run AC loads
up to 1440 W (continuously). Run times for the AC loads will depend on
the amp-hour capacity of the batteries and the total of the loads drawing
power through the unit.
Types to use
The following battery types are recommended for use with the PowerHub
1800:
Voltage
12 Vdc (required) (100 Ah minimum)
Chemistry
SEALED, lead-acid batteries (required), Gel-type
(recommended), AGM (acceptable)
Size
Standard Group 27. Maximum dimension of battery to be 12" W ×
6.75" D × 9" H (including terminal posts)
Terminal Location
Top (required)
Terminal Type
L-type or screw-in terminal
Important:
The PowerHub 1800 is designed to be permanently connected to a
small 12-volt battery bank. Do not operate this equipment without connecting a
battery or battery bank.
WARNING
ELECTRIC SHOCK HAZARD
Do not use terminal adaptors in the battery box they may short circuit the battery.
Failure to follow these instructions can result in death or serious injury.
Figure 2-2
Battery Box and Battery Size
Battery Box holds 2 Standard Sealed
Lead-acid 12 Vdc Batteries*
sized 12" W × 6.75" D × 9" H
9"
6.75"
12"
Battery Box
Internal
dimensions
12.75" W x 16"D
16"
12.75"
975-0289-01-01(PowerHub_1800_IG).book Page 5 Thursday, June 4, 2015 9:49 AM
Summary of Contents for PH1800-GFP
Page 2: ...975 0289 01 01 PowerHub_1800_IG book Page 2 Thursday June 4 2015 9 49 AM ...
Page 20: ...ii 975 0289 01 01 PowerHub_1800_IG book Page ii Thursday June 4 2015 9 49 AM ...
Page 30: ...1 10 975 0289 01 01 PowerHub_1800_IG book Page 10 Thursday June 4 2015 9 49 AM ...
Page 66: ...3 26 975 0289 01 01 PowerHub_1800_IG book Page 26 Thursday June 4 2015 9 49 AM ...
Page 74: ...2 975 0289 01 01 PowerHub_1800_IG book Page 2 Thursday June 4 2015 9 49 AM ...
Page 75: ...975 0289 01 01 PowerHub_1800_IG book Page 3 Thursday June 4 2015 9 49 AM ...