Wiring
975-0289-01-01
3–11
Terminal Access
Figure 3-9
Terminal Access for Hardwiring
Table 3-1
Recommended Wire Gauges for Input and Output Terminals
Terminal
Acceptable Wire Gauge
Torque to.....
AC Input (Neutral and Line)
#14 AWG
1.3 Nm (11.5 in-lbs)
AC Output (Neutral and Line)
#14 AWG
1.3 Nm (11.5 in-lbs)
AC Ground
#14 AWG
1.8 Nm (16.0 in-lbs)
DC Input (32 A DC Input/40 A fused)
Manufacturer’s recommendation.
20.3 Nm (180 in-lbs)
Remove the 5 #6-32
Phillips screws on
the top of the
inverter. Lift off the
panel to expose the
terminals.
Wiring Terminals Enlargement
BEFORE REMOVING INVERTER COVER:
Check to ensure the AC Indicator LED is NOT
illuminated and that there are absolutely no
sources of power connected to the PowerHub.
AC Indicator LED
Once hardwiring is complete 120 Vac power will be
available at the outlets on the front panel as well as the
outlets directly connected to the PowerHub through the
AC Distribution Panel.
975-0289-01-01(PowerHub_1800_IG).book Page 11 Thursday, June 4, 2015 9:49 AM
Summary of Contents for PH1800-GFP
Page 2: ...975 0289 01 01 PowerHub_1800_IG book Page 2 Thursday June 4 2015 9 49 AM ...
Page 20: ...ii 975 0289 01 01 PowerHub_1800_IG book Page ii Thursday June 4 2015 9 49 AM ...
Page 30: ...1 10 975 0289 01 01 PowerHub_1800_IG book Page 10 Thursday June 4 2015 9 49 AM ...
Page 66: ...3 26 975 0289 01 01 PowerHub_1800_IG book Page 26 Thursday June 4 2015 9 49 AM ...
Page 74: ...2 975 0289 01 01 PowerHub_1800_IG book Page 2 Thursday June 4 2015 9 49 AM ...
Page 75: ...975 0289 01 01 PowerHub_1800_IG book Page 3 Thursday June 4 2015 9 49 AM ...