15. 12V Out to Expansion:
This jumper should be installed when connecting the Expansion port to
another CM8X8/MRC88 Keypad.
16. Zone Termination.
Jumper. Do not remove jumper if there is only one keypad in a zone. If there is
more then one keypad in a zone, remove from all but the last keypad in the daisy chain configuration.
17. IR Receiver Enable.
Jumper. Enables IR sensor on Keypad. Remove when using an external IR
receiver or if experiencing IR interference from external sources (Plasma, LCD, Fluorescent lights,
Sunlight etc…)
18. IR In-Zone.
2-Terminal WECO style socket - Zone IR out for local ‘In-Zone’ emitter out. Used for IR
control of equipment in the same location as the CSPLCD. Output equivalent to that of Xantech
Amplified Connecting blocks. 100mA peak output. Connect directly to Emitter or to Xantech Connecting
Blocks (789-44 or 791-44).
19. Power Input & IR Output Terminal:
a. +16VDC
: For connection from 16VDC CSPLCD Power Supply (Models SPLCDPS1 &
SPLCDPS4)
b. GND:
Power Supply and IR GND connection
c. STATUS:
5-30VDC Status Input for Macro Trigger or LED power Indication
from
remote
device or 12VDC STATUS output from CSPLCD
to
remote device. (Use Universal Dragon
Drop-IR to configure terminal as a Status Input or Status Output).
d. IR
BUS:
IR Output from CSPLCD to be connected to Xantech Connecting Blocks (i.e. 789-44,
791-44, CB60 etc.)
20. External IR Input.
4-Terminal WECO style socket – Allows connection of other Xantech IR Receivers
and/or Keypads to be used in conjunction with the CSPLCD. RC68+ commands received here can
trigger internal IR and/or RS232 Macro’s to be outputted on IR BUS terminal and/or Serial RJ45
terminal.
21. SERIAL:
This is a bi-directional RS422 Serial port that can be run up to 4000ft (1.2KM) to communicate
with a remote RS232 device. This uses a standard CAT5 cable terminated in RJ45 connectors on both
sides. The RS422232 converter and a 12VDC Power Supply (both sold separately) are required