22
Peristaltic Pumps
Tighten the Tube Clip
1. Peristaltic Pump Connector
2. Peristaltic Pump
3. Outlet Tube
4. Liquid Tube Clip
5. Inlet Tube
M2.5*8*4.5 Hexagon socket combination screw
P20/P30 2019 Peristaltic Pump
P20/P30 2019 Peristaltic Pump Seal
*5
*1
*1
SKU-02-004-00429
SKU-05-002-00580
SKU-02-001-03429
💡
What do we need in this section:
1.
Drain all liquid and residues from the liquid tube, then uses a 2.5 screwdriver to remove
the 2 screws securing the Peristaltic Pump. Remove the Tube Clip on the Outlet Tube and
disconnect the Outlet Tube.
The screws using M2.5*8*4.5 Hexagon socket combination screw here.
2.
Reassemble the Peristaltic Pump to its original position, then firmly connect the Outlet and
Inlet tube. Once it is secured, tighten the Tube Clip and tighten the screws to re-secure the
Peristaltic Pump.
🔧
Disassemble:
❶
❷
❸
❹
❺
@2020 XAG Australia All Rights Reserved