1.
Reassemble the Motor Housing Protective Pad, upper part of the Motor Housing Kit and
Motor Top Housing in order and tighten the screws to re-secure each component.
2.
Reassemble the Nozzle Indicator back into original position.
Reconnect and secure the nozzle indicator connector, and gently pushes the connector
back into the Airframe Arm.
3.
Pass the Nozzle Indicator wiring behind the Motor Mount Arm Clamp.
4.
Reassemble the Motor Case (Bottom) and Spray Disc in order and tighten the screws to re-
secure each component.
I.
Before reassembling, be aware of the screw model and do not miss or reassemble with
wrong screw.
II.
Avoid liquid or foreign matter when connecting or disconnecting the connectors.
IMPORTANT:
The screws using 2.5 screwdriver is the M3*8*6 Hexagon socket combination screw here.
The screws using 1.0 screwdriver is the M2*6*5 Hexagon socket combination screw here.
🛠
Assemble: