6-8
TriCoder Setup Parameters
Default settings are shown in bold print. The number or letter associated with
the setting is the same whether configuring the TriCoder using the bar coded
Setup Menu or via the keypad in PROGRAMMING MODE. Some parameters
are set only by the bar code setup menu or only by the TriCoder keypad.
Beep Tone
Lowest 0
Low 1
Medium
2
High 3
Highest 4
No Beep, No LED on tethered scanner
5
No Beep, but LED on tethered scanner shows good
read
6
The TriCoder allows five different beep pitches or no beep at all.
Speaker Volume
Speaker and beeper volume are also controlled by keyboard Setup in
PROGRAMMING MODE. The default is 5, a medium setting. If you want it
louder, enter a larger number. If you want it less loud, enter a lower number.
Code 3 of 9 (Code 39)
Enable Code 3 of 9
0
Disable Code 3 of 9
1
Enable Full ASCII Code 39
2
Disable Full ASCII Code 39
3
Enable Code 39 Accumulate Mode
4
Disable Code 39 Accumulate Mode
5
Enable Start/Stop character transmission
6
Disable Start/Stop character transmission
7
Enable Mod 43 Check Digit
8
Disable Mod43 Check Digit
9
Enable Check Digit transmission
A
Disable Check Digit transmission
B
Caps Lock ON
C
Caps Lock OFF
D
•
The Start and Stop character for Code 39 is the
*
character. Settings
6
and
7
determine whether or not those characters are transmitted to the
computer along with the data. For example, at setting
6
, the data of
1234
would be transmitted as
*1234*
. Transmitting the start and stop