14-15
Fail-safe Re-initialization Procedure
Here is a fail-safe way to re-initialize the TriCoder and set it back to the
factory defaults: (also useful for deleting a data file and programs no longer
needed).
1. After turning on the TriCoder, answer NO to all prompts until you
see
NON PORTABLE MODE?
KEY [YES/NO]?_
At the NON PORTABLE MODE prompt, press the
F1
key.
2. Press
the
SHIFT
key.
3. Press
the
D
key. After pressing the
D
key, you should see the
prompt:
PLEASE ENTER
DIAG. COMMAND_
4. Press
the
SHIFT
key.
5. Now
press
one
of the following keys depending on what you want
to happen:
Press the
6
key to delete only the current data file.
Or
Press the
7
key to delete programs 1-3.
Or
Press the
8
key to load default programs, set program
voice messages to 00, and leave error voice messages
unassigned.
Or
Press the
9
key to load default programs, sets program
voice and error messages to defaults.
Or
Press the
0
key to load default programs but clear all
voice to unassigned and all program voice messages to
00.
6. Press
the
F1
key to go back to the opening screen.